system env temperature threshold yellow
system env temperature threshold yellow
Use the system env temperature threshold yellow global configuration command on the switch stack
or on a standalone switch to configure the difference between the yellow and red temperature thresholds
that determines the value of yellow threshold. Use the no form of this command to return to the default
value.
system env temperature threshold yellow value
no system env temperature threshold yellow value
Syntax Description
Defaults These are the default values:
Command Modes Global configuration
Command History
Usage Guidelines You cannot configure the green and red thresholds but can configure the yellow threshold. Use the
system env temperature threshold yellow value global configuration command to specify the
difference between the yellow and red thresholds and to configure the yellow threshold. For example, if
the red threshold is 60 degrees C and you want to configure the yellow threshold as 51 degrees C, set the
difference between the thresholds as 15 by using the system env temperature threshold yellow 9
command.
Note The internal temperature sensor in the switch measures the internal system temperature and might vary
±5 degrees C.
value Specify the difference between the yellow and red threshold values (in Celsius). The
range is 10 to 25. The default value is 14.
Table 2-56 Default Values for the Temperature Thresholds
Switch
Difference
between Yellow
and Red Red
1
1. You cannot configure the red temperature threshold.
Catalyst 3750-X and Catalyst 3560-X 14°C 60°C