January 2016
6-49
WorkCentre 4150/4250/4260WorkCentre 4150/4250/4260WorkCentre Work-
GP 17, GP 18
General Procedures and Information
GP 17 Restriction of Hazardous Substances (RoHS)
Purpose
To give information on the RoHS Directive.
The RoHS Directive restricts the use of certain hazardous substances in electrical and elec-
tronic equipment. It applies to equipment placed in the European Union (EU) market. The
directive takes effect from 1st July 2006.
The hazardous substances are:
• Lead (Pb)
• Mercury (Hg)
• Cadmium (Cd)
• Hexavalent Chromium (Cr 6+, Cr [VI])
• Polybrominated Diphenyl Ethers (PBDE’s)
• Polybrominated Biphenyls (PBB’s)
Identification of a RoHS Compliant Machine
Xerox will maintain a central list of RoHS compliant machines.
This general procedure is for information only. All WorkCentre 4150/4250/4260/4265 machines
are RoHS compliant.
GP 18 Scan Edge Print
Purpose
Use this procedure to test the document edge detection routine.
Procedure
NOTE: Before performing the scan edge print, ensure the DADF is lowered.
Perform the following:
1. Enter diagnostics, GP 1.
2. Select the Scan Edge routine:
• 4150/4250/4260: Select Other Routines > Scan Edge Print.
• 4265: Select Copier Diagnostics > Scan Edge > Print.
3. Exit diagnostics. The scan edge print will be printed.
4. If the following co-ordinates are displayed, the scan edge print is good:
Valid Image [ 0: 80] [ 0: 416]
Scan Image [ 0: 320] [ 0: 1664]