January 2016
6-53
WorkCentre 4150/4250/4260WorkCentre 4150/4250/4260WorkCentre Work-
dC001, dC104
General Procedures and Information
dC001 Reset Auditron Master PIN (4150)
Purpose
To reset the Auditron and the System Administration password to the default, (1111).
NOTE: The Auditron and the System Administration password is the same item.
Procedure
1. Enter diagnostics, GP 1.
2. Select Diagnostic Routines, then select Other Routines, then select 001 Reset
Auditron Master PIN.
3. Select Reset Auditron Master PIN.
4. Select confirm or cancel.
dC104 Usage Counters (4265)
Purpose
The purpose is to provide the CSE with information regarding images sent, hours of use, total
impressions, and types of impressions printed.
Procedure
1. Enter diagnostics, GP 1.
2. Select Service Information.
3. Select dC 104 Usage Counters.
4. The following selections are available:
•Images Sent
• Server Fax Images Sent
• Email Images Sent
• Network Scanning Images Sent
• Total Impressions
• Black Impressions
• Black Copied Impressions
• Black Printed Impressions
• Sheets
• Copied Sheets
• Black Copied Sheets
• Printed Sheets
• Black Printed Sheets
• 2-Sided Sheets
• Copied 2-Sided Sheets
• Black Copied 2-Sided Sheets
• Printed 2-Sided Sheets
• Black Printed 2-Sided Sheets
• Maintenance Impressions
• Black Maintenance Impressions
• Black Stored Images Printed Impression
• Attempted Original Sheet Feeds in the DADF
• Jammed Papers in the DADF
• Known Jams in the IOT
• Known Jams in the Finishing Device(s)
• Fax Images Received
• Fax Impressions
• Power On Impressions
• Attempted Sheet Feeds from Internal Trays
• Actual Sheet Feeds from Internal Trays