Commands listed in alphabetical order
MEASUrement?
(Query Only)
This query-only command returns all measurement parameters.
Group
Measurement
Syntax
MEASUrement?
Examples
MEASUREMENT? might return :MEASUREMENT:GATING
OFF;IMMED:TYPE UNDEFINED;UNITS "V";SOURCE1 CH1;SOURCE2
CH1;SOURCE1:SIGTYPE PULSE;:MEASUREM ENT:IMMED:SOURC E2:SIGTYPE
PULSE;:MEASUREMENT:IMMED: DELAY:EDGE1 RISE;EDGE2
RISE;DIRECTION FORWARDS;:MEASUREMEN T:IMMED:REFLEVE L:METHOD
PERCENT;ABSOLUTE:HIGH 0.0000;LOW 0.0000;MID1 0.0000;MID2
0.0000;:MEASUREMENT:IMMED :REFLEVEL:PERCENT:HIGH 90 .0000;LOW
10.0000;MID1 50.0000;MID2 50.0000;:MEASUREMENT:IMM ED:METHOD
HISTOGRAM;NOISE HIGH;:MEASUREMENT:M EAS1:STATE
0;TYPE UNDEFINED;UNITS "V";SOURCE1 CH1;SOURCE2
CH1;SOURCE1:SIGTYPE PULSE;:MEASUREM ENT:MEAS1:SOURC E2:SIGTYPE
PULSE;:MEASUREMENT:MEAS1: DELAY:EDGE1 RISE;EDGE2
RISE;DIRECTION FORWARDS;:MEASUREMEN T:MEAS1:REFLEVE L:METHOD
PERCENT;ABSOLUTE:HIGH 0.0000;LOW 0.0000;MID1 0.0000;MID2
0.0000;:MEASUREMENT:MEAS1 :REFLEVEL:PERCENT:HIGH 90 .0000;LOW
10.0000;MID1 50.0000;MID2 50.0000;:MEASUREMENT:MEA S1:METHOD
HISTOGRAM;NOISE HIGH;:MEASUREMENT:M EAS2:STATE
0;TYPE UNDEFINED;UNITS "V";SOURCE1 CH1;SOURCE2
CH1;SOURCE1:SIGTYPE PULSE;:MEASUREM ENT:MEAS2:SOURC E2:SIGTYPE
PULSE;:MEASUREMENT:MEAS2: DELAY:EDGE1 RISE;EDGE2
RISE;DIRECTION
.
MEASUrement:ADDMEAS (No Query Form)
This command adds a measurement.
Group
Measurement
Syntax
MEASUrement:ADDMEAS
{ACCOMMONMODE|ACRMS|AMPlI TUDE|AREA|BASE|BITAMPLITUDE|
BITHIGH|BITLOW|BURSTWIDTH |COMMONMODE|DATARATE|DCD|DDJ|DELAY|
DJ|DJDIRAC|EYEHIGH|EYELOW |FALLSLEWRATE|FALLTIME|FREQUENCY|
F2|F4|F8|HEIGHT|HEIGHTBER |HIGH|HIGHTIME|HOLD|JITTERSUMMARY|
J2|J9|LOW|LOWTIME|MAXIMUM |MEAN|MINIMUM|NDUty|
NOVERSHOOT|NPERIOD|NPJ|NW IDTTH|PDUTY|