Commands listed in alphabetical order
MEASUrement:R
EF1:REFLevels:ABSolute:HYSTe resis?
might return
:MEASUREMENT:REF1:REFLEVEL S:ABSOLUTE:HYSTERESIS 30. 0000E-3
indicating the hysteresis is 30.0 mV.
MEASUrement
:REF<x>:REFLevels:ABSolute:RISEHigh
This command sets or queries the value used as the high reference level of the
rising edge when the measurement's ref level method is set to absolute.
Group
Measurement
Syntax
MEASUrement:REF<x>:REFLeve ls:ABSolute:RISEHigh <NR3>
MEASUrement:REF<x>:REFLeve ls:ABSolute:RISEHigh?
Arguments
<NR3> is the value used as the high reference level of the rising edge when the
measurement's ref level method is set to absolute.
Examples
MEASUrement:REF1:REFLevels :ABSolute:RISEHigh 1.5 sets the
reference level to 1.5 V.
MEASUrement:REF1:REFLevels :ABSolute:RISEHigh? might return
:MEASUREMENT:REF1:REFLEVEL S:ABSOLUTE:RISEHIGH 1.000 0 indicating
the reference level is 1.0 V.
MEASUrement:REF<x>:REFLevels:ABSolute:RISELow
This command sets or que ries the value used as the low reference l evel of the
rising edge when the measurement's ref level method is set to absolute.
Group
Measurement
Syntax
MEASUrement:REF<x>:REFLeve ls:ABSolute:RISELow <NR3>
MEASUrement:REF<x>:REFLeve ls:ABSolute:RISELow?
Arguments
<NR3> is the v alue used as the low reference level of the rising edge when the
measurement's ref level method is set to absolute.
Examples
MEASUrement:REF1:REFLevels :ABSolute:RISELow -1.5 sets the
reference level to -1.5 V.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-509