Commands listed in alphabetical order
Examples
MEASUREMENT:C
LOCKRECOVERY:CONSTCLOCKMODE MEAN
sets the constant
clock mode to MEAN.
MEASUREMENT:
CLOCKRECOVERY:CONSTCLOCKMO DE?
might return
:MEASUREMENT:CLOCKRECOVER Y:CONSTCLOCKMODE MEAN indicating the
constant clock mode is set to MEAN.
MEASUremen
t:CLOCKRecovery:DAMPing
This command sets or queries the global damping value used when PLL clock
recovery is used for the measurement. This will affect measurements whose
:MEASUre
ment:MEAS<x>:CLOCKRecovery:GLOBal ag is set to 1.
Group
Measurement
Syntax
MEASUrement:CLOCKRecovery :DAMPing <NR3>
MEASUrement:CLOCKRecovery :DAMPing?
Arguments
<NR3> is the global clock recovery damping value.
Examples
MEASUREMENT:CLOCKRECOVERY :DAMPING
:MEASUREMENT:CLOCKRECOVER Y:DAMPING?
might return
:MEASUREMENT:CLOCKRECOVER Y:DAMPING 700.0000E-3 indicating the
damping value is set to
MEASUrement:CLOCKRecovery:DATAPath
This command sets or queries the global le containing the data pattern used when
known data pattern clock recovery is used for the measurement. This will affect
measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal
ag is set to 1.
Group
Measurement
Syntax
MEASUrement:CLOCKRecovery :DATAPath <QString>
MEASUrement:CLOCKR
ecovery:DATAPath?
Arguments
<QString> is the path and lename, in quotes, of the le containing the data
pattern.
2-394 MSO54, MSO56, MSO58, MSO58LP Programmer

Table of Contents

Other manuals for Tektronix MSO58

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO58 and is the answer not in the manual?

Tektronix MSO58 Specifications

General IconGeneral
BrandTektronix
ModelMSO58
CategoryTest Equipment
LanguageEnglish

Related product manuals