EasyManuals Logo
Home>Tektronix>Test Equipment>MSO58

Tektronix MSO58 User Manual

Tektronix MSO58
1026 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #598 background imageLoading...
Page #598 background image
Commands listed in alphabetical order
POWer:POWer<
x>:SOA:ISOURce
This command sets or queries the current source for SOA measurement in the
specied power measurement badge. The power measurement badge is specied
by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:SOA:ISOURc e {CH<x> | MATH<x> | REF<x>}
POWer:POWer<x>:SOA:ISOURc e?
Arguments
CH<x> = A channel specier; <x> is 1 through 8 and is limited by the number
of FlexChannels in your instrument.
MATH<x> = A math waveform specier; <x> is 1.
REF<x> = A reference waveform specier; <x> is 1.
Examples
POWer:POWer1:SOA:ISOURce CH2 sets the current source for SOA
measurement as channel 2.
POWer:POWer<x>:SOA:POINT
This command sets or queries the Y co-ordinate va lue for SOA mask.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:SOA:POINT <QString> <NR1>
POWer:POWer<x>:SOA:POINT <QString>?
Arguments
<QString> = 1Y | 2Y | 3Y | 4Y | 5Y | 6Y | 7Y | 8Y | 9Y | 10Y | 11Y | 12Y | 13Y
| 14Y | 15Y | 16Y | 17Y | 18Y | 19Y | 20Y | 21Y | 22Y | 23Y | 24Y | 25Y | 26Y
| 27Y | 28Y | 29Y | 30Y | 31Y | 32Y
<NR1> ranges from –5000 to 5000
2-582 MSO54, MSO56, MSO58, MSO58LP Programmer

Table of Contents

Other manuals for Tektronix MSO58

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO58 and is the answer not in the manual?

Tektronix MSO58 Specifications

General IconGeneral
BrandTektronix
ModelMSO58
CategoryTest Equipment
LanguageEnglish

Related product manuals