Commands listed in alphabetical order
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:FLE Xray:FRAMEID:HIVALue <QSt ring>
TRIGger:{A|B}:BUS:B<x>:FLE Xray:FRAMEID:HIVALue?
Arguments
<QString> is a quoted string that is the binary frame ID high value.
Examples
TRIGGER:A:BUS:B1:FLEXRAY:F RAMEID:HIVALUE "11001100101" sets the
frame ID high value to 11001100101.
TRIGGER:A:BUS:B1:FLEXRAY:F RAMEID:HIVALUE? might return
TRIGGER:A:BUS:B1:FLEXRAY:F RAMEID:HIVALUE "XXXXXXXXXXX"
indicating the frame ID high value is "don't care".
TRIGger:{A|B}:BUS:B<x>:FLEXray:FRAMEID:QUALifier
This command specifies the qualifier to use when triggering on the FlexRay
bus frame ID field. The trigger condition needs to be set to IDentifier (using
TRIGger:{A|B}:BUS:B<x>:FLEXray:CONDition). The bus number is specified
by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:FLE Xray:FRAMEID:QUALifier {L ESSthan|
MOREthan|EQual|UNEQual|LES SEQual|MOREEQual|INrange|OUTrange}
TRIGger:{A|B}:BUS:B<x>:FLE Xray:FRAMEID:QUALifier?
Arguments
LESS
than
sets the frame ID qualifier to less than.
MOREthan sets the frame ID qualifier to greater than.
EQual sets the frame ID qualifier to equal.
UNEQual sets the frame ID qualifier to not equal.
LESSEQual sets the frame ID qualifier to less than or equal.
MOREEQual sets the frame ID qualifier to greater than or equal.
INrange sets the frame ID qualifier to in range.
O
UTrange
sets the frame ID qualifier to out of range.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-801