Commands listed in alphabetical order
Examples
TRIGGER:A:BUS
:B1:MIL1553B:STATUS:BIT:TF ON
Especifies filtering
status words for those where the TF bit has a value of 1.
TRIGGER:A:BU
S:B1:MIL1553B:STATUS:BIT:T F?
might return NOCARE,
indicating that status words are not being filtered based on the TF bit value.
TRIGger:{A|B}:BUS:B<x>:MIL1553B:STATus:PARity
This command sets or queries the value of the status word parity bit for a
MIL-STD-1553 bus to triggering on. The bus number is specified by x. The
trigger condition must be set to STATus.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MI L1553B:STATus:PARity
{ONE|ZERo|NOCARE}
TRIGger:{A|B}:BUS:B<x>:MI L1553B
:STATus:PARity?
Arguments
ONE filters status words to only match those where the parity bit has a value of 1.
ZERo filters status words to only match those where the parity bit has a value of 0.
NOCARE disables filtering of status words on the parity bit.
Examples
TRIGGER:A:BUS:B1:MIL1553B :STATUS:PARITY ONE specifies filtering
status words for those where the parity bit has a value of 1.
TRIGGER:A:BUS:B1:MIL1553B :STATUS:PARITY? might return NOCARE,
indicating that status words are not being filtered based on the parity bit value.
TRIGger:{A|B}:BUS:B<x>:MIL1553B:TIMe:LESSLimit
This command sets or queries the lower limit to be used when triggering on
response time / inter message gap time for a MIL-STD-1553 bus. The bus number
is specified by x. The trigger condition must be set to TIMe.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
2-828 MSO54, MSO56, MSO58, MSO58LP Programmer