Commands listed in alphabetical order
Syntax
POWer:POWer<x
>:HARMONICS:VSOURce
{CH<x> | MATH<x> | REF<x>}
POWer:POWer<x>:HARMONICS: VSOURce?
Arguments
CH<x> = A channel specifier; <x> is 1 through 8 and is limited by the number
of FlexChannels in your instrument.
MATH<x> = A math waveform specifier; <x> is ≥1.
REF<x> = A reference waveform specifier; <x> is ≥1.
Examples
POWer:POWer1:HARMONICS:VS OURce CH1 sets the voltage source for
harmonics measurement as channel 1.
POWer:POWer<x>:LABel
This command sets or queries the label for the specified power measurement. As
the label can contain non 7-bit ASCII text, it is stored in Percent Encoding format.
The power measurement badge is specified by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:LABel <QString>
POWer:POWer<x>:LABel?
Examples
POWer:POWer1:LABel "NewMeasurement" sets the custom measurement
name for the measurement in Power 1 badge as New Measurement.
POWer:POWer<x>:LINERIPPLE:INPUTSOurce
This command sets or queries the input source for line ripple measurement in the
specified power measurement badge. The power measurement badge is specified
by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
2-544 MSO54, MSO56, MSO58, MSO58LP Programmer