Table 2-34: Power commands (cont.)
Command Description
POWer:POWer<x>:CYCLEMin:
INPUTSOurce
Sets or queries the input source for cycle minimum measurement in the specied power
measurement badge.
POWer:POWer<x>:CYCLEPKPK:
INPUTSOurce
Sets or queries the input source for cycle peak-to-peak measurement in the specied power
measurement badge.
POWer:POWer<x>:CYCLETop:
INPUTSOurce
Sets or queries the input source for cycle top measurement in the specied power
measurement badge.
POWer:POWer<x>:DIDT:
INPUTSOurce
Sets or queries the input source for di/dt measurement in the specied power measurement
badge.
POWer:POWer<x>:DIDT:
SOURCEEDGEType
Sets or queries the edge type for di/dt measurement in the specied power measurement
badge.
POWer:POWer<x>:DVDT:
INPUTSOurce
Sets or queries the input source for dv/dt measurement in the specied power measurement
badge.
POWer:POWer<x>:DVDT:
SOURCEEDGEType
Sets or queries the edge type for dv/dt measurement in the speci ed power measurement
badge.
POWer:POWer<x>:FREQUENCY :
EDGe
Sets or queries the edge type for frequency measurement in the specied power measurement
badge.
POWer:POWer<x>:FREQUENCY :
INPUTSOurce
Sets or queries the input source for frequency measurement in the specied power
measurement badge.
POWer:POWer<x>:GATing Sets or queries the gating type for the specied power measurement badge.
POWer:POWer<x>:GATing:
GLOBal
Sets or queries the gating settings for the specied power measurement badge.
POWer:POWer<x>:HARMONICS:
CLASs
Sets or queries the class type for the harmonics measurement in the specied power
measurement badge.
POWer:POWer<x>:HARMONICS:
CMEThod
Sets or queries the fundamental current method for the harmonics measurement in the
specied power measurement badge.
POWer:POWer<x>:HARMONICS:
FUNDCURRent
Sets or queries the fundamental current value for the harmonics measurement in the specied
power measurement badge.
POWer:POWer<x>:HARMONICS:
HORDer
Sets or queries the order value for the harmonics measurement in the specied power
measurement badge.
POWer:POWer<x>:HARMONICS:
HSOURce
Sets or queries the source type for the harmonics measurement in the specied power
measurement badge.
POWer:POWer<x>:HARMONICS:
IPOWer
Sets or queries the input power value for the harmonics measurement in the specied power
measurement badge.
POWer:POWer<x>:HARMONICS:
ISOURce
Sets or queries the current source for SOA measurement in the specied power measurement
badge.
POWer:POWer<x>:HARMONICS:
ODDEVen
Sets or queries the harmonics value analysis format in the specied power measurement
badge.
POWer:POWer<x>:HARMONICS:
PFACtor
Sets or queries the value of power factor fo r the harmonics measurement in the specied
power measurement badge.
POWer:POWer<x>:HARMONICS:
POWERRating
Sets or queries the power level for the harmonics measurement in the specied power
measurement badge.
2-56 MSO54, MSO56, MSO58, MSO58LP Programmer

Table of Contents

Other manuals for Tektronix MSO58