Appendix D: Waveform Transfer (WFMOutpre and CURVe Query) Examples
XUNIT "Hz"
This value indicates the units of the x-axis of the waveform record. This value is always “Hz”
for RF frequency domain traces. This is query only. (If you would like to determine only this
value, use the
WFMOutpre:XUNit? query.)
XINCR 2.0000
E+6
This value in
dicates the frequency, in hertz, between data points in the waveform record.
This is query only. (If you would like to determine only this value, use the WFMOutpre:XINcr?
query.)
XZERO 1.4000E+9 This value indicates the frequency, in hertz, of the rst data point in the waveform record.
This freque
ncy is relative to the time of the trigger, which is always 0. This XZEro frequency
can be negative. This is query only. (If you would like to determine only this value, use
the WFMOutpre:XZEro? query.)
PT_OFF 0 This is a query provided only for compatibility with other Tektronix oscilloscopes. The
returned
valueisalways0. (Ifyouwouldliketo determine only this value, use the
WFMOutpre:PT_Off? query.)
YUNIT "W"
This value indicates the units of data points in the waveform record. This value depends on
the vertical units of the source waveform i n this case, watts. This is query only. (If you
would li
ke to determine only this v alue, use the WFMOutpre:YUNit? query.)
YMULT 1.5625E-3
This val
ue indicates the multiplying factor to convert the data point values to the units
specied by the:WFMOutpre:YUNit command. This is query only. (If you would like to
determine only this value, use the WFMOutpre:YMUlt? query.)
YOFF 0.0E+0 This value indicates the vertical position of the source waveform. This value is unused for
RF fre
quency domain traces and is always 0.
YZERO
0.0E+0
This v
alue indicates the vertical offset of the source waveform. This value is unused for R F
frequency domain traces and is always 0.
DOMAIN FREQ UE NCY This value indicates the domain in w hich the source waveform is displayed and stored. For
RF time domain traces, the domain is Time and waveform transfer information is treated
as in
teger information. For RF frequency domain traces, the domain is Frequency and
waveform transfer information is treated as oating point information. This is query only. (If
you would like to determine only this value, use the WFMO utpre:DOMain? query.)
WFMTYPE RF_FD
This value i ndicates the type of the source waveform. RF_FD indicates an R F frequency
dom
ain trace (frequency domain waveform). This is query only. (If you would like to
determine only this value, use the WFMOutpre:WFMTYPe? query.)
CENTERFREQUENCY 2.4000E+9 This v alue indicates the center frequency, in hertz, of the source waveform. This is query only.
(If you would like to determine only this value, use the WFMOutpre:CENTERFREQuency?
qu
ery.)
S
PAN 2.0000E+9
T
his value indicates the frequency span, in hertz, of the source waveform. This is query
only. (If you would like to determine only this value, use the WFMOutpre:SPAN? query.)
R
EFLEVEL 1.0000E-3
This value indicates the reference level, in watts, of the source waveform. This is query only.
(If you would like to determine only this value, use the WFMOutpre:REFLEvel? query.)
MSO54, MSO56, MSO58, MSO58LP Programmer D-17

Table of Contents

Other manuals for Tektronix MSO58

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO58 and is the answer not in the manual?

Tektronix MSO58 Specifications

General IconGeneral
BrandTektronix
ModelMSO58
CategoryTest Equipment
LanguageEnglish

Related product manuals