Clear the CTNEQPT-MISMATCH Condition
SUMMARY STEPS
1. Determine what kind of card is preprovisioned in the slot by completing the following steps:
2. Complete the Physically Replace a Card, on page 453 procedure for the mismatched card.
DETAILED STEPS
Step 1 Determine what kind of card is preprovisioned in the slot by completing the following steps:
a) In node view, click the Inventory tab.
b) View the slot row contents in the Eqpt Type and Actual Eqpt Type columns.
The Eqpt Type column contains the equipment that is provisioned in the slot. The Actual Eqpt Type contains the
equipment that is physically present in the slot.
Step 2 Complete the Physically Replace a Card, on page 453 procedure for the mismatched card.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
DATA-CRC
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Object: OCH, MSISC
A data cyclic redundancy check (CRC) bad packet count condition occurs when excessive CRC errors are
received on the trunk ports of the GE-XP, GE-XPE, 10GE-XP, and 10GE-XPE cards.
The CRC error rate is measured and compared against a configured threshold. The system can be configured
to perform an automatic FAPS switch when the DATA-CRC alarm occurs.
Clear the DATA-CRC Alarm
SUMMARY STEPS
1. For GE-XP, GE-XPE, 10GE-XP, and 10GE-XPE cards, perform the following:
DETAILED STEPS
For GE-XP, GE-XPE, 10GE-XP, and 10GE-XPE cards, perform the following:
a) Ensure that the fiber connector for the card is completely plugged in.
b) If the BER threshold is correct and at the expected level, use an optical test set to measure the power level of the line
to ensure it is within guidelines. For specific procedures to use the test set equipment, consult the manufacturer.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
163
Alarm Troubleshooting
Clear the CTNEQPT-MISMATCH Condition

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals