EasyManuals Logo
Home>Cisco>Network Hardware>NCS 2000 series

Cisco NCS 2000 series Troubleshoot Manual

Cisco NCS 2000 series
602 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #226 background imageLoading...
Page #226 background image
Use of controls, adjustments, or performing procedures other than those specified could result in
hazardous radiation exposure. Statement 1057
Warning
If a circuit shows a partial status when the EOC or EOC-L alarm is raised, it occurs when the logical circuit
is in place. The circuit is able to carry traffic when the DCC termination issue is resolved. You do not need
to delete the circuit when troubleshooting this alarm.
Note
Clear the EOC-L Alarm
SUMMARY STEPS
1. Complete the "Clear the EOC Alarm" procedure.
DETAILED STEPS
Complete the "Clear the EOC Alarm" procedure.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
High-performance devices on this card can get hot during operation. To remove the card, hold it by the
faceplate and bottom edge. Allow the card to cool before touching any other part of it or before placing
it in an antistatic bag. Statement 201
Warning
EQPT
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Objects: AICI-AEP, AICI-AIE, EQPT, PPM
An Equipment Failure alarm indicates that a hardware failure has occurred on the reporting card. If the EQPT
alarm occurs with a BKUPMEMP, refer to the procedure to clear the alarm. (Clearing a BKUPMEMP alarm
also clears an EQPT alarm.)
This alarm is also invoked if a diagnostic circuit detects a card application-specific integrated circuit (ASIC)
failure. In this case, if the card is part of a protection group, an APS switch occurs. If the card is the protect
card, switching is inhibited and a PROTNA , on page 363, is raised. The standby path generates a path-type
alarm. For more information about provisioning PPMs (SFPs), refer to the Installing the GBIC, SFP, SFP+,
and XFP Optical Modules in Cisco ONS Platforms document.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
180
Alarm Troubleshooting
Clear the EOC-L Alarm

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals