Clear the EQPT Alarm
SUMMARY STEPS
1. If traffic is active on the alarmed port, you could need to switch traffic away from it. See the Protection
Switching, Lock Initiation, and Clearing, on page 443 procedure for commonly used traffic-switching
procedures.
2. Complete the Reset a Card in CTC, on page 449 procedure for the reporting card.
3. Verify that the reset is complete and error-free and that no new related alarms appear in CTC. Verify the
LED status. A green ACT/SBY LED indicates an active card. An amber ACT/SBY LED indicates a
standby card.
4. If the CTC reset does not clear the alarm, complete the Remove and Reinsert (Reseat) Any Card , on page
452 procedure for the reporting card.
5. If the physical reseat of the card fails to clear the alarm, complete the Physically Replace a Card, on page
453 procedure for the reporting card.
DETAILED STEPS
Step 1 If traffic is active on the alarmed port, you could need to switch traffic away from it. See the Protection Switching, Lock
Initiation, and Clearing, on page 443 procedure for commonly used traffic-switching procedures.
Step 2 Complete the Reset a Card in CTC, on page 449 procedure for the reporting card.
Step 3 Verify that the reset is complete and error-free and that no new related alarms appear in CTC. Verify the LED status. A
green ACT/SBY LED indicates an active card. An amber ACT/SBY LED indicates a standby card.
Step 4 If the CTC reset does not clear the alarm, complete the Remove and Reinsert (Reseat) Any Card , on page 452 procedure
for the reporting card.
High-performance devices on this card can get hot during operation. To remove the card, hold it by the
faceplate and bottom edge. Allow the card to cool before touching any other part of it or before placing
it in an antistatic bag. Statement 201
Warning
Step 5 If the physical reseat of the card fails to clear the alarm, complete the Physically Replace a Card, on page 453 procedure
for the reporting card.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at http://www.cisco.com/c/en/us/support/index.html for more information or log into http://www.cisco.com/c/
en/us/support/web/tsd-cisco-worldwide-contacts.html to obtain a directory of toll-free Technical Support numbers for
your country.
EQPT-DEGRADE
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Objects: EQPT
The Equipment Degrade condition is raised when a permanent failure that limits or compromises the normal
behavior of the card (without impact on traffic) is detected.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
181
Alarm Troubleshooting
Clear the EQPT Alarm

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals