Forward Error Correction
In DWDM spans, FEC reduces the quantities of retiming, reshaping, and regeneration (3R) needed to maintain
signal quality. The following two PM parameters are associated with FEC:
BIT-EC: Bit errors corrected (BIT-EC ) indicates the number of bit errors corrected in the DWDM trunk
line during the PM time interval.
UNC-WORDSThe number of uncorrectable words detected in the DWDM trunk line during the PM
time interval.
Complete the following procedure to provision BIT-EC and UNC-WORDS PM parameters for FEC.
Provision Card FEC Thresholds
SUMMARY STEPS
1. In node view (single-shelf mode) or shelf view (multishelf mode), double-click a transponder, muxponder,
or xponder card to open the card view.
2. Click the Provisioning > OTN > FEC Thresholds tabs.
3. In the Bit Errors Corrected field, enter a threshold number, for example 225837.
4. In the Uncorrectable Words field, enter a threshold number, for example, 2.
5. In the Intervals area, click 15 Min.
DETAILED STEPS
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), double-click a transponder, muxponder, or xponder
card to open the card view.
Step 2 Click the Provisioning > OTN > FEC Thresholds tabs.
Step 3 In the Bit Errors Corrected field, enter a threshold number, for example 225837.
Step 4 In the Uncorrectable Words field, enter a threshold number, for example, 2.
Step 5 In the Intervals area, click 15 Min.
Sample Trouble Resolutions
The following sample trouble resolutions use PM and TCAs to isolate degrade points.
Problem There is a BBE TCA on a single transponder pair.
Possible Cause The transponder input power is out of range.
Solution Check the input power on the transponder. It should be within the specified/supported range.
Possible Cause There are dirty trunk connectors on the transponder.
Solution Check the connector on the trunk port.
Possible Cause There is a degraded trunk patchcord between the transponder and the DWDM port.
Solution Check the patchcord on the transponder DWDM port.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
32
General Troubleshooting
Forward Error Correction

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals