VOLT-MISM
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: PWR
The Power Monitoring Mismatch Between Control Cards alarm is raised against the shelf when the power
voltages of both the control cards are out of range of each other by more than 3V DC.
Clear the VOLT-MISM Condition
SUMMARY STEPS
1. Check the incoming voltage level to the shelf using a voltmeter. Follow site practices or refer to the Install
the Shelf and Common Control Cards chapter in the Configuration guide for power installation procedures.
2. Correct any incoming voltage issues.
DETAILED STEPS
Step 1 Check the incoming voltage level to the shelf using a voltmeter. Follow site practices or refer to the Install the Shelf and
Common Control Cards chapter in the Configuration guide for power installation procedures.
Step 2 Correct any incoming voltage issues.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
WAITING-TO-START
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: OTS
The WAITING-TO-START condition is raised on the COM-TX and EXP-TX ports of 16-WXC-FS, 17 SMR9
FS, 24 SMR9 FS, 34 SMR9 FS, and SMR20 FS cards by the control cards when a cross-connection is ready
to start and/or waiting for other transient conditions to clear. The condition clears when cross-connection is
running in In-Service administrative state .
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/
index.html for more information or call Cisco TAC (1 800 553-2447).
WAN-SYNCLOSS
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: STSMON, STSTRM
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
434
Alarm Troubleshooting
VOLT-MISM

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals