EasyManuals Logo
Home>Cisco>Network Hardware>NCS 2000 series

Cisco NCS 2000 series Troubleshoot Manual

Cisco NCS 2000 series
602 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #418 background imageLoading...
Page #418 background image
DETAILED STEPS
Step 1 Use optical time domain reflectometer (OTDR) to identity any excess loss between the Raman card LINE-RX port and
the customer fibre. After the inspection, a new Raman Calibration is triggered and if the physical problem is fixed, the
alarm will clear.
Step 2 If the alarm is caused by a set-up problem, re-verify all node installation steps and manually trigger a Raman Calibration.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
RAMAN-CALIBRATION-PENDING
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: OTS
The RAMAN-CALIBRATION-PENDING condition is raised on the EDRA-1-xx, EDRA-2-xx, and
RAMAN-CTP cards when automatic Raman pump calibration is scheduled to run repeatedly after the first
installation or fiber cut. The condition is cleared when the Raman pump calibration succeeds or fails for 30
attempts.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/
index.html for more information or call Cisco TAC (1 800 553-2447).
RAMAN-CALIBRATION-RUNNING
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Object: OTS
The RAMAN-CALIBRATION-RUNNING alarm is raised on the EDRA-1-xx, EDRA-2-xx, and RAMAN-CTP
cards when the Raman pump calibration is running. The alarm is cleared when the Raman pump calibration
succeeds or fails.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/
index.html for more information or call Cisco TAC (1 800 553-2447).
RAMAN-G-NOT-REACHED
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: OTS
The RAMAN-G-NOT-REACHED alarm is raised on the OPT-RAMP-C, OPT-RAMP-CE, EDRA-1-xx,
EDRA-2-xx, and RAMAN-CTP cards when the Raman gain value is lower than the ANS target. The alarm
also occurs after a cut restoration procedure fails to restore the expected Raman gain set point.
The Fiber Cut Recovery field in the Maintenance > Installation tab in the card view of CTC displays the
status as "Failed" and the Raman gain value is lower than the set point.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
372
Alarm Troubleshooting
RAMAN-CALIBRATION-PENDING

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals