ELWBATVG
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Object: PWR
The Extreme Low Voltage Battery alarm occurs in a 48 VDC environment when a battery lead input voltage
falls below the extreme low power threshold. This threshold, with a default value of 40.5 VDC, is
user-provisionable. The alarm remains raised until the voltage remains over the threshold for 120 seconds.
Clear the ELWBATVG Alarm
SUMMARY STEPS
1. The problem is external to the ONS system. Troubleshoot the power source supplying the battery leads.
DETAILED STEPS
The problem is external to the ONS system. Troubleshoot the power source supplying the battery leads.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at http://www.cisco.com/c/en/us/support/index.html for more information or log into http://www.cisco.com/c/
en/us/support/web/tsd-cisco-worldwide-contacts.html to obtain a directory of toll-free Technical Support numbers for
your country.
ENCAP-MISMATCH-P
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Object: STSTRM
The Encapsulation C2 Byte Mismatch Path alarm applies to ML-Series Ethernet cards or the CE-1000 card.
It occurs when the first three following conditions are met and one of the last two is false:
The received C2 byte is not 0x00 (unequipped).
The received C2 byte is not a PDI value.
The received C2 does not match the expected C2.
The expected C2 byte is not 0x01 (equipped unspecified).
The received C2 byte is not 0x01 (equipped unspecified).
For an ENCAP-MISMATCH-P to be raised, there is a mismatch between the received and expected C2 byte,
with either the expected byte or received byte value being 0x01.
For example, an ENCAP-MISMATCH-P alarm is raised if a circuit created between two ML-Series or two
CE-1000 cards has generic framing procedure (GFP) framing provisioned on one end and HDLC framing
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
174
Alarm Troubleshooting
ELWBATVG

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals