There is a read error from the backplane EEPROM during boot-up. The
TNC/TSC/TNCE/TSCE/TNCS/TNCS-O cards use the default MAC address (00:11:22:33:44:55).
There is a read error occurring on one of the redundant control cards that read the address from the
backplane; these cards read the address independently and could therefore each read different address
values.
Clear the INVMACADR Alarm
SUMMARY STEPS
1. Complete the Resetting the Controller Card procedure for TNC/TNCE/TSC/TSCE/TNCS/TNCS-O cards.
2. If the reset card has not rebooted successfully, or the alarm has not cleared, log into the Technical Support
Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1
800 553-2447).
DETAILED STEPS
Step 1 Complete the Resetting the Controller Card procedure for TNC/TNCE/TSC/TSCE/TNCS/TNCS-O cards.
Wait ten minutes to verify that the card you reset completely reboots and becomes the standby card.
Step 2 If the reset card has not rebooted successfully, or the alarm has not cleared, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
IMPROPRMVL-FS
Default Severity: Minor (MI), Non-Service-Affecting (NSA)
Logical Objects: PSHELF
The Improper Removal of Fiber Shuffle ( IMPROPRMVL-FS) condition occurs when a provisioned and
associated Passive Shelf is unplugged from its USB Port. It occurred due to an improper removal of the device.
The condition will clears when the Passive Shelf is plugged back in the USB port. This transient condition
does not result in a standing condition.
IPC-LASER-FAIL
Default Severity: Minor (MI), Non-Service-Affecting (NSA)
Logical Objects: EQPT
The Internal Patch-cord Connection (IPC) Laser Fail alarm is raised when the laser fails to produce output
power. The laser failure is detected when the laser is powered up. The laser is embedded inside 20SMR FS
CV card for connection verification.
The alarm is cleared automatically when laser output power is detected during or after a power module reset.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
242
Alarm Troubleshooting
Clear the INVMACADR Alarm

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals