372
Cisco Nexus 3548 Switch NX-OS Unicast Routing Command Reference
OL-27852-01
Chapter Unicast Routing Commands
threshold weight
threshold weight
To set a threshold weight for a tracked object in a list of objects, use the threshold weight command. To
disable the threshold weight, use the no form of this command.
threshold weight {up number [down number] | down number [up number]}
no threshold weight
Syntax Description
Command Default None
Command Modes Tracking configuration mode
Command History
Usage Guidelines When you configure a tracked list using the track object-number list command, there are two keywords
available: boolean and threshold. If you specify the threshold keyword, you can specify either the
percentage or weight keywords. If you specify the percentage keyword, the weight keyword is
unavailable. If you specify the weight keyword, the percentage keyword is unavailable.
You should configure the up weight first. The valid range is from 1 to 255. The available down weight
depends on what you have configured for the up weight. For example, if you configure 25 for up, you
will see a range from 0 to 24 for down.
This command does not require a license.
Examples This example shows how to configure the tracked list 12 to measure a threshold using a specified weight:
switch# configure terminal
switch(config)# track 11 list threshold weight
switch(config-track)# object 1
switch(config-track)# object 2
switch(config-track)# threshold weight up 35 down 22
switch(config-track)#
up Specifies the up threshold.
down (Optional) Specifies the down threshold.
number Threshold value. The range is from 1 to 255.
Release Modification
5.0(3)A1(1) This command was introduced.