ELECTRICVEHICLE-BATTERYCHARGERChargerTroubleshooting
15
TERMINALBLOCKCOVER
Theterminalblockcoverpreventswaterexposureandpreventsashortacrosstheterminals,whichwillblowthe
30-ampfuseinthechargerreceptaclewireharness.
RESETTINGPOWER–EXTERNALCHARGER
Thetriangularstatusindicatorlightonthechargercomesoninasolidredstatetocommunicateasignicantcharger
hardwareorsoftwarefailure.SeeExternalChargerStatusIndicatorsonpage15-4.Beforereplacingthecharger,
however,resetthechargerincasethefailurewascausedbyatemporarysituation.Toresetchargerpower,take
thefollowingsteps:
1.UnplugtheDCcordfromthevehicle.
2.UnplugtheACcordfromtheACpowersource.
3.Waitfortheredlighttogooff,wait30seconds,thenplugtheACcordintotheACpowersource.
4.WhentheblueACstatusindicatorlightcomeson,connecttheDCcordtothevehicle.
5.Ifthetriangularstatusindicatorlightcomeson,contactyourClubCardealer.Ifthelightdoesnotcomeback
on,attempttochargethecarasusual.
RESETTINGPOWER–ONBOARDCHARGER
Thetriangularstatusindicatorlightonthechargercomesoninasolidredstatetocommunicateasignicantcharger
hardwareorsoftwarefailure.SeeExternalChargerStatusIndicatorsonpage15-4.Beforereplacingthecharger,
however,resetthechargerincasethefailurewascausedbyatemporarysituation.Toresetchargerpower,take
thefollowingsteps:
1.UnplugtheACcordfromtheACpowersource.
2.DisconnecttheDCcordundertherear-facingseat.
3.Waitfortheredlighttogooff,wait30seconds,thenplugtheACcordintotheACpowersource.
4.WhentheblueACstatusindicatorlightcomeson,reconnecttheDCcordundertherear-facingseat.
5.Ifthetriangularstatusindicatorlightcomeson,contactyourClubCardealer.Ifthelightdoesnotcomebackon,
attempttochargethevehicleasusual.
2020Precedent,Villager2and4MaintenanceandServiceManualPage15-15