Page 6.2 - 8 COMBIVERT F5-A, -E, -H © KEB, 2012-10
Start-up
The speed controller parameters must be adapted to the ap-
plication
The maximum voltage controller must be parameterized if the
eld weakening range is used.
12. Test run
Activate control release (terminal X2A.16) and make a test
run, whether the drive runs stable in all speed ranges and
under all load conditions
If error messages occur during the start-up phase, read chapter 8.1 „Error causes and displays“.
6.2.1.3 Vector controlled operation with encoder feedback with motor model
Attention: With this start-up description it is provided that an incremental encoder to encoder interface 1 (15pole
Sub D socket X3A) is used for speed feedback.
Also it must be secured that the motor phases and the incremental encoder are correct wired (in phase, large
surface of shield connection, well grounding).
The motor temperature sensor must be connected.
A controlled start-up (U/f - characteristic) of the drive can be executed for examination in case of insecurity
about the phase allocation (motor and incremental encoder).
1. Open control release
deactivate terminal X2A.16
inverter state ru.00 = „noP“/„0: no control release“
2. Selection of the speed range
The required speed range (e.g.: 0..+/- 4000 rpm) is selected
in control type ud.02.
ud.02 control type = 4…7
The speed range should be selected at least 10% higher
than the highest setpoint speed in the application.
Attention: Changing the control type re-
leases loading of the default parameters!
All data for the adjustment of the control
type (e.g. resolution of the speed, etc.)
see chapter 5.1.
3. Loading the default parameters
Loading the default parameters (KEB factory setting) by
Fr.01 copy parameter set = - 4
Attention: Pre-adjustments (e.g. function
of the digital inputs) disappear
4.
Selectionofthecontrollerconguration

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5-H and is the answer not in the manual?

KEB COMBIVERT F5-H Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5-H
CategoryControl Unit
LanguageEnglish

Related product manuals