EasyManuals Logo
Home>Parker>DC Drives>Compax3 Series

Parker Compax3 Series User Manual

Parker Compax3 Series
414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #265 background imageLoading...
Page #265 background image
Parker EME
Setting up Compax3
192-120114 N5 C3I22T11 June 2008 265
4.3.9.7 Overview of the user interface
In this chapter you can read about:
Selection of the signal or system to be measured. .......................................................... 265
Frequency settings .......................................................................................................... 270
velocity control ................................................................................................................. 271
Other settings .................................................................................................................. 273
Operating and status field................................................................................................ 275
Display of the measurement result .................................................................................. 277
Dispaly of the measurement poin
t at the cursor position................................................. 278
5
2
6
3
1
4
(1)
Selection of the signal or system to be measured (see page 265)
(2)
Frequency settings (see page 270)
(3)
Other settings (see page 273)
(4)
Operating and status field (see page 275)
(5)
Display of the measurement result (see page 277)
(6)
Dispaly of the measurement point at the cursor position (see page 278)
Selection of the signal or system to be measured.
In this chapter you can read about:
Current control ................................................................................................................. 266
Mechanical system .......................................................................................................... 267
Position control ................................................................................................................ 268
With the aid of the tree structure, you may select what you want to measure. Here,
the selection is made, if a frequency spectrum or a frequency response is to be
measured.
The shown structures are simplified in such as all feedbacks are displayed without
special transmission behavior. This is surely not the case in reality, serves however
a better overview.

Table of Contents

Other manuals for Parker Compax3 Series