Parker EME
Error
192-120114 N5 C3I22T11 June 2008 339
Standard error reactions:
Reaction 2: Downramp with "de-energize" then apply brake (see page 287) and
finally de-energize.
For errors with standard reaction 2 the
error reaction can be changed (see page
152).
Reaction 5: switch-off of the current immediately (without ramp), application of the
brake.
Caution! A Z-axis may drop down due to the brake delay times
Most pending errors can be acknowledged with Quit!
The following errors must be acknowledged with Power on:
0x7381, 0x7382, 0x7391, 0x7392, 0x73A0
Object 550.1 displays error:
value 1 means "no error".
The errors as well as the error history can be viewed in the C3 ServoManager un-
der optimization (at the top right of the optimization window).
7.1 Error list
Detailed information on the topic of the "error list" can be found in the online help of
the device.
7. Error