Command groups
Table 2-31: Measurement commands (cont.)
Command
Description
MEASUrement:MEAS<x>:CCRESUlts:
ALLAcqs:MINimum?
This query-only command returns the minimum cycle-cycle value for the specied
measurement for all acquisitions.
MEASUrement:MEAS<x>:CCRESUlts:
ALLAcqs:PK2PK?
This query-only command returns the peak to peak cycle-cycle statistic for the
specied measurement for all acquisitions.
MEASUrement:MEAS<x>:CCRESUlts:
ALLAcqs:POPUlation?
This query-only command returns the population of all cycle-cycle statistics for the
specied measurement for all acquisitions accumulated since statistics were last reset.
MEASUrement:MEAS<x>:CCRESUlts:
ALLAcqs:STDDev?
This query-only command returns the standard deviation cycle-cycle for the specied
measurement for all acquisitions.
MEASUrement:MEAS<x>:CCRESUlts:
CURRentacq:MAXimum?
This query-only command returns the maximum cycle-cycle value for the specied
measurement for the current acquisition.
MEASUrement:MEAS<x>:CCRESUlts:
CURRentacq:MEAN?
This query-only command returns the mean cycle-cycle value for the specied
measurement for the current acquisition.
MEASUrement:MEAS<x>:CCRESUlts:
CURRentacq:MINimum?
This query-only command returns the minimum cycle-cycle value for the specied
measurement for the current acquisition.
MEASUrement:MEAS<x>:CCRESUlts:
CURRentacq:PK2PK?
This query-only command returns the peak to peak cycle-cycle statistic for the
specied measurement for the current acquisition.
MEASUrement:MEAS<x>:CCRESUlts:
CURRentacq:POPUlation?
This query-only c ommand returns the populatio n of the cycle-cycle statistics for the
specied measurement for the current acquisition.
MEASUrement:MEAS<x>:CCRESUlts:
CURRentacq:STDDev?
This query-only command returns the standard deviation cycle-cycle for the specied
measurement for the current acquisition.
MEASUrement:MEAS<x>:CLOCKRecovery:
ADVanced:METHod
This command sets or queries the advanced clock recovery method when advanced
clock recovery is used for the measurement.
MEASUrement:MEAS<x>:CLOCKRecovery:
CLOCKFrequency
This command sets or queries the clock frequency used when xed constant clock
recovery is used for the measurement.
MEASUrement:MEAS<x>:CLOCKRecovery:
CLOCKMultiplier
This command sets or queries the clock multiplier used when explicit clock recovery
is used for the measurement.
MEASUrement:MEAS<x>:CLOCKRecovery:
CONSTCLOC KMODe
This command sets or queries the constant clock m ode used when constant clock
recovery is used for the measurement.
MEASUrement:MEAS<x>:CLOCKRecovery:
DAMPing
This command sets or queries the damping value used when PLL clock recovery
is used for the measurement.
MEASUrement:MEAS<x>:CLOCKRecovery:
DATAPath
This command sets or queries the le containing the data pattern used when known
data pattern clock recovery is used for the measurement.
MEASUrement:MEAS<x>:CLOCKRecovery:
DATARate
This command sets or queries the nominal data bit rate when nominal data rate clock
recovery is used for the measurement.
MEASUrement:MEAS<x>:CLOCKRecovery:
EXPLICITCLOCKMODe
This command sets or queries the explicit clock mode used when explicit clock
recovery is used for the measurement.
MEASUrement:MEAS<x>:CLOCKRecovery:
GLOBal
This command sets or queries the clock recovery settings global ag for the
measurement.
2-44 MSO54, MSO56, MSO58, MSO58LP Programmer

Table of Contents

Other manuals for Tektronix MSO58

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO58 and is the answer not in the manual?

Tektronix MSO58 Specifications

General IconGeneral
BrandTektronix
ModelMSO58
CategoryTest Equipment
LanguageEnglish

Related product manuals