EasyManuals Logo
Home>Wintriss>Controller>SmartPAC2

Wintriss SmartPAC2 User Manual

Default Icon
383 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
1126700 SmartPAC 2 User Manual
4-4 Initialization Mode
To set the POSITION SENSOR MODE parameter, follow these instructions:
1. If you installed a position sensor, select the “ENABLED” entry, using the ENTER key.
The POSITION SENSOR INPUT item should read ON when the position sensor magnet
is centered beneath the magnetic switch (see page 2-40).
2. If you did not install a position sensor, set this entry to “DISABLED,” which is the factory
setting.
3. Press RESET when done.
Resolver Motion Mode (Normal Motion – Link Motion)
(INITIALIZATION – POSITION SENSOR)
This item controls whether SmartPAC 2 adapts to the action of a link-motion press. The
default setting is “NORMAL MOTION.” If your SmartPAC 2 is installed on a link-motion
press, go to Using SmartPAC 2 with a Link-motion Press, page 4-42 for instructions.
Angle Wheel Rotation (Clockwise – Counterclockwise)
(INITIALIZATION – POSITION SENSOR)
This setting controls the rotational direction of the crank angle clock on the SmartPAC 2
display. The default setting is “CW” (Clockwise). If you want the crank angle clock to rotate
in a counterclockwise direction, press ENTER with the ANGLE WHEEL ROTATION item
selected and “CW” displayed.
Tool Number Mode
(INITIALIZATION – POSITION SENSOR)
This item enables you to select which format–Numeric or Alphanumeric–is used to enter tool
numbers in SmartPAC 2. In Numeric mode, tool numbers are limited to 7 digits and contain
only numbers. Alphanumeric tool “numbers” can contain 20 characters, including both letters
and numbers. Other differences between the two tool number modes are shown in Table 4-2.
Before you set up your SmartPAC 2, decide which tool number mode you will use, numeric or
alphanumeric. Set up your SmartPAC 2 in that mode, and do not change tool number modes
afterward.
UPGRADING FROM ORIGINAL SMARTPAC
See When You Upgrade from an Original SmartPAC, page 4-5 and Appendix D for more
information about managing tool number mode when upgrading from original SmartPAC to
SmartPAC 2.
NOTICE
NOTICE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wintriss SmartPAC2 and is the answer not in the manual?

Wintriss SmartPAC2 Specifications

General IconGeneral
BrandWintriss
ModelSmartPAC2
CategoryController
LanguageEnglish

Related product manuals