1126700 SmartPAC 2 User Manual
6-8 Run Mode
On this screen, you can change or reset the programmed strokes, good parts, batch and total
hits counters and presets if you have the appropriate security access (see Table 4-5,
page 4-25). For instructions on entering counter and preset values, see COUNTERS,
page 5-9.
If you have set the CHANGE COUNTS parameter on the Security Access Menu in
Initialization to PROGRAM AND RUN MODES (see page 4-25), you can reset batch counts
to the values you have programmed for batch pre-loads (see Setting Batch Pre-Load Counts,
page 5-15). When the CHANGE COUNTS feature is enabled for Run mode, the label
RELOAD BATCH COUNTERS displays to the left of the F2 function key (see Figure 6-10),
and F2 becomes active. To reset batch counts to their pre-load values, simply press F2.
Pre-load values display in the Count field for the batches you have programmed with those
values.
When messages display indicating that counter presets have been reached, press RESET to
clear the message (see Counter Preset Reached Messages, page 7-2).
Figure 6-10. Counters Screen with “Reload Batch Counters” Function
When the Total Hits counter reaches its preset value, a flashing message, “Total Hits Preset,”
appears in the Status Box at the top of the screen. To clear this message, set the Total Hits preset
to zero (0), then reset this value to the desired quantity. See COUNTERS, page 5-9.