10 Advanced Usage
10 - 18
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
About Multi-trigger Imaging Task and Input Image processing items
• The Input Image processing items that can be allocated in the Multi-trigger Imaging Task process-
ing item are the following.
FH series Sensor Controller
• [Camera Image Input FH], [Camera Image Input HDR], and [Camera Image Input HDR-Lite].
FZ5-800/1100/1200 series Sensor Controller
• [Camera Image Input], [Camera Image Input HDR], and [Camera Image Input HDR-Lite].
• Always use at least one Input Image processing unit within the processing range of Multi-trigger
Imaging Task processing item (Multi-trigger Imaging Task block).
• When there are multiple Camera Image Input HDR processing items or Camera Image Input
HDR-Lite processing items in one Multi-trigger Imaging Task block, the system will operate with
the setting [Non-Multi-input] mode, even if you select [Multi-input] mode.
• When there are multiple Input Image processing items in one Multi-trigger Imaging Task block, the
system will operate with the setting [Non-Multi-input] mode, even if you select [Multi-input] mode.
Restrictions in allocating processing items
• Do not attempt settings like below by using "Conditional Branching" or "Selective Branching pro-
cessing items.
• Settings to move from WITHIN the range between Multi-trigger Imaging processing item and
Multi-trigger Imaging End processing item to OUTSIDE of it, or that in reversed direction.
• Settings to move between the Multi-trigger Imaging Task blocks.
• Do not allocate Input Image processing items to the following positions.
• Position higher than Multi-trigger Imaging processing item (such as unit 0)
• Position between the Multi-trigger Imaging processing item and Multi-trigger Imaging Task
processing item.
• Do not refer the data between the Multi-trigger Imaging Task blocks for calculations.
About parallel processing
• If parallel processing is activated (if you select ON for the [Parallel Execute] settings in the [Sys-
tem settings]), Multi-trigger Imaging Task block is executed in parallel. The processing items in a
task block are not processed in parallel, but executed sequentially.
• The number of Multi-trigger Imaging Task blocks that can be performed in parallel is same as the
number of CPU cores.
• If parallel processing is disabled, Multi-trigger Imaging Task blocks are executed sequentially.
About image mode
• If the Image mode of the Image Window Setting is set as [Through], flow is executed automatically
as the controller does in the previous system.