3 - 35
3 Basic Operations
Vision System FH/FHV/FZ5 Series Users Manual (Z365)
3-6 Saving Settings before Turning OFF the Power and
Restarting
3
3-6-2 Device Information Storage Tool
This tool will prevent issues happening at start-up of the Sensor Controller due to recognition delay for
external devices. Be sure to execute this tool when connecting external devices. For example, the fol-
lowing issues can be solved.
In the case where the operation log save destination is set to an external device, the Sensor Control-
ler fails to save operation records at start-up.
In the case where a scene group is saved in an external device, the Sensor Controller fails to load the
scene group at start-up.
When performing a measurement just after the start-up of the Sensor Controller, image logging into
an external device fails.
Important
Once this tool was utilized, the external device information cannot recover the factory set-
tings even when [System initialization] in [Function] menu is executed.
Remote operation is not supported.
When executing this tool, the following information at the time of the tool executed is stored
in the Sensor Controller.
Information on connected external storage such as device drivers and drive letters.
Information on communication settings such as IP addresses.
If you changed the connecting configuration of external storage, or communication settings
such as IP addresses ([Tool] [System settings] [Communication] [Ethernet] set-
tings), be sure to execute this tool again.
The information saved by this tool cannot be transferred to another Sensor Controller with
“Configuration copy” tool. Execute this tool per the Sensor Controller.
The information for all connected external devices is memorized. Execute this tool after
removing unnecessary external devices to memorize.
Some of external devices out of operation guarantee need to install a special driver. When
using this tool in a state of such external devices connected, the Sensor Controller might
incorrectly operate. Do not execute this tool in such condition.
When a Sensor Controller after this tool was executed is started up with network drives con-
nected, the startup time might become longer.
1 Turn on the Sensor Controller after connecting all external devices.
2 In the Main Window, select [Tool] [Device information storage tool]. The following dialog box
is displayed.
3-6-2 Device Information Storage Tool
Using the tool

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh-1 series and is the answer not in the manual?

Omron fh-1 series Specifications

General IconGeneral
BrandOmron
Modelfh-1 series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals