3 - 35
3 Basic Operations
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
3-6 Saving Settings before Turning OFF the Power and
Restarting
3
3-6-2 Device Information Storage Tool
This tool will prevent issues happening at start-up of the Sensor Controller due to recognition delay for
external devices. Be sure to execute this tool when connecting external devices. For example, the fol-
lowing issues can be solved.
• In the case where the operation log save destination is set to an external device, the Sensor Control-
ler fails to save operation records at start-up.
• In the case where a scene group is saved in an external device, the Sensor Controller fails to load the
scene group at start-up.
• When performing a measurement just after the start-up of the Sensor Controller, image logging into
an external device fails.
• Once this tool was utilized, the external device information cannot recover the factory set-
tings even when [System initialization] in [Function] menu is executed.
• Remote operation is not supported.
• When executing this tool, the following information at the time of the tool executed is stored
in the Sensor Controller.
• Information on connected external storage such as device drivers and drive letters.
• Information on communication settings such as IP addresses.
If you changed the connecting configuration of external storage, or communication settings
such as IP addresses ([Tool] → [System settings] → [Communication] → [Ethernet] set-
tings), be sure to execute this tool again.
• The information saved by this tool cannot be transferred to another Sensor Controller with
“Configuration copy” tool. Execute this tool per the Sensor Controller.
• The information for all connected external devices is memorized. Execute this tool after
removing unnecessary external devices to memorize.
• Some of external devices out of operation guarantee need to install a special driver. When
using this tool in a state of such external devices connected, the Sensor Controller might
incorrectly operate. Do not execute this tool in such condition.
• When a Sensor Controller after this tool was executed is started up with network drives con-
nected, the startup time might become longer.
1 Turn on the Sensor Controller after connecting all external devices.
2 In the Main Window, select [Tool] → [Device information storage tool]. The following dialog box
is displayed.
3-6-2 Device Information Storage Tool
Using the tool