11 - 11
11 What to Do!
Vision System FH/FHV/FZ5 Series Users Manual (Z365)
11-2 FAQ
11
11-2-3 For Measurement
Software keyboard is not displayed
When the keyboard is connected to the sensor controller, the software keyboard is not displayed.
Please input characters with the connected keyboard.
During remote operation, if the keyboard is connected to the PC on the remote control side, the
software keyboard will not be displayed.
The image will not be displayed when remeasuring saved images
You may be using the through image mode in the image display pane on the used layouts.
If you are used the through image mode in the image display pane, the image will not be dis-
played. Check the image mode for all used and unused image display pane.
Refer to "Arranging Windows" (Refer to 8-3 Arranging Windows [Layout Functions] on page 8-14)
and check the image display mode specifications for all 24 image display panes.
Display is not updated.
Measurement is given priority when the STEP signal input interval is short or continuous mea-
surement is being performed. As a result, the measurement results (overall judgment, image, indi-
vidual judgment in the flow display, detailed results) may not be updated. When continuous
measurement ends, the measurement results for the final measurement are displayed.
The measurement NG (image mismatch) error will result when connecting a
monochrome camera
Immediately after performing such operation as starting up the FH series / FZ5 series Sensor
Controller, changing scenes, and clearing measurement results, there will be no input image. If
you edit the settings or press the OK button in the Properties Dialog Box with no input image, the
error will occur at the next measurement.
If you open the Properties Dialog Box and click the OK button to close the dialog box with no input
image, the settings will automatically switch to the factory default settings for the color cameras. If
measuring an image input from the monochrome camera with these settings, the error will result
due to the mismatching color modes between the camera and the settings.
To correct the settings after the error occurrence, input the image from the monochrome camera
and open the Properties Dialog Boxes for each processing unit. Click the OK button on each
screen to exit the screen.
Target figure for the processing unit figure setting has disappeared
This occurs when image input or image compensation-related units, such as filtering, are set
between the processing unit figure setting and the unit to be changed.
Processing Items List Manual
Processing Item List > Supporting Inspection and Measurement > Processing Unit Figure Setting
Refer to the [Important] section of the aforementioned.
Judgement (JG) value is -10
The judgement will be -10 when there is incompatibility between the scene setting and the input
image. Could the image be a color image even though it is loaded to a scene that is set for a
monochrome camera? Please check the setting.
Communication takes time
When you select [Through image], communication will more take time from executing the commu-
nication command to completion of it.
If the communication time will take more time, select [Freeze].
Confirm the device configuration or communication cycle, i.e. Polling cycle of PLC Link or EtherNet/IP.
11-2-3 For Measurement

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh-1 series and is the answer not in the manual?

Omron fh-1 series Specifications

General IconGeneral
BrandOmron
Modelfh-1 series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals