Table 2-31: Measurement commands (cont.)
Command
Description
MEASUrement:FILTers:HIGHPass:FREQ This command sets or queries the global high pass lter frequency.
MEASUrement:FILTers:HIGHPass:SPEC This command sets or queries the global high pass lter order.
MEASUrement:FILTers:LOWPass:FRE Q This command sets or queries the global low pass lter cutoff frequency.
MEASUrement:FILTers:LOWPass:SP EC This command sets or queries the global low pass lter order.
MEASUrement:FILTers:RAMPtime This command sets or queries the global lter ramp ti me.
MEASUrement:GATing
This command sets or queries the global gating type.
MEASUrement:GATing:ACTive This command sets or queries the global gating active level used for logic gating.
MEASUrement:GATing:HYSTeresis This command sets or queries the global gating hysteresis value used for logic gating.
MEASUrement:GATing:LOGICSource This command sets or queries the gating data source used for logic gating.
MEASUrement:GATing:MIDRef This command sets or queries the global gating mid ref value used for logic gating.
MEASUrement:GATing:SEARCHSource This command sets or queries the global gating search source used for logic gating.
MEASUrement:INTERp
This command sets or queries the interpol ation mode used to locate edge crossings.
MEASUrement:JITTermodel This command sets or queries the model used to separate random from deterministic
jitter for jitter measurements.
MEASUrement:LIST? Lists all currently de ned measurements.
MEASUrement:LOCKRJ Sets or queries the state of RJ locking.
MEASUrement:LOCKRJValue Sets or queries the RJ lock value.
MEASUrement:MATH<x>:REFLevels:ABSolute:
FALLHigh
This command sets or queries the value used as the high reference level of the falling
edge when the source ref level method is set to absolute.
MEASUrement:MATH<x>:REFLevels:ABSolute:
FALLLow
This command sets or queries the value used as the low reference level of the falling
edge when the source ref level method is set to absolute.
MEASUrement:MATH<x>:REFLevels:ABSolute:
FALLMid
This command sets or queries the value used as the mid reference level of the falling
edge when the source ref level method is set to absolute.
MEASUrement:MATH<x>:REFLevels:ABSolute:
HYSTeresis
This command sets or queries the value of the hysteresis of the reference level when
the s ource ref level method is set to absolute.
MEASUrement:MATH<x>:REFLevels:ABSolute:
RISEHigh
This command sets or queries the value used as the high reference level of the rising
edge when the source ref level method is set to absolute.
MEASUrement:MATH<x>:REFLevels:ABSolute:
RISELow
This command sets or queries the value used as the low reference level of the rising
edge when the source ref level method is set to absolute.
MEASUrement:MATH<x>:REFLevels:ABSolute:
RISEMid
This command sets or queries the value used as the mid reference level of the rising
edge when the source ref level method is set to absolute.
MEASUrement:MATH<x>:REFLevels:ABSolute:
TYPE
This command sets or queries the reference level type for the source.
MEASUrement:MATH<x>:REFLevels:BASETop This command sets or queries the method used to calculate the TOP and BASE used
to calculate reference levels for the source.
2-42 MSO54, MSO56, MSO58, MSO58LP Programmer

Table of Contents

Other manuals for Tektronix MSO58

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO58 and is the answer not in the manual?

Tektronix MSO58 Specifications

General IconGeneral
BrandTektronix
ModelMSO58
CategoryTest Equipment
LanguageEnglish

Related product manuals