2. RADAR, CHART RADAR OPERATION
2-20
3. To anchor the VRM, push the left button.
To turn off a VRM, click the arrow in the applicable VRM box. The VRM disappears
and the VRM box is minimized.
2.16.2 How to set VRM attributes
You can customize the VRMs to suit your needs.
1. Open the menu then select [3 NAV TOOL] and [2 EBL•VRM] (B type) or [2
EBL•VRM•CURSOR] (IMO and A types) to display the [EBL•VRM] menu
(EBL•VRM•CURSOR menu for the IMO and A types).
2. For the B-type radar, select [3 VRM1] or [4 VRM2] as appropriate. Spin the
scrollwheel to select desired unit then push the left button.
3. Select [6 VRM TTG] and then select the VRM(s) that are to show/hide the TTG
indication. [OFF] shows no TTG indication.
4. The [LINK EBL] option for [7 VRM OFFSET] automati-
cally activates the corresponding VRM when the offset
EBL is enabled.
5. Close the menu.
B-type radar
IMO- and A-type radars
000
010
020
030
040
050
060
070
080
090
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
Offset
EBL
VRM

Table of Contents

Other manuals for Furuno FCR-2139S-BB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FCR-2139S-BB and is the answer not in the manual?

Furuno FCR-2139S-BB Specifications

General IconGeneral
BrandFuruno
ModelFCR-2139S-BB
CategoryMarine Radar
LanguageEnglish

Related product manuals