v 1.0 — February 2020 Altanium Matrix5
130 Set the Remote Standby Delay Timer
To set the Remote Standby Duration Timer, do the steps that follow:
1. On the System Setup screen, touch the Heats Setup tab and then touch the Control
Page 1 tab.
2. Touch the Remote Standby Duration Timer field that is below Remote Standby.
3. Enter the time requirement in this format: HHMMSS.
4. Touch the Accept button.
10.17.3 Set the Remote Standby Delay Timer
The Remote Standby Delay Timer is a feature available with remote standby. Use this delay
timer to protect the product material, so it does not get burned if the molding machine is
stopped for a specified time period. If the Remote Standby Delay Timer is set, the Altanium
controller will not decrease the temperatures until the delay time has elapsed.
For example, when the operator gate on the molding machine is opened, a signal to start the
Remote Standby Delay Timer could be sent to the Altanium controller. If the operator gate is
closed before the delay time has elapsed, the controller will not enter standby. If the operator
gate stays open, the controller then enters standby.
NOTE: If the remote standby feature is not installed on the system, only the Manual Standby
Duration Timer setting is shown on the screen.
To set the Remote Standby Delay Timer, do the steps that follow:
1. On the System Setup screen, touch the Heats Setup tab and then touch the Control
Page 1 tab.
2. Touch the Remote Standby Delay Timer field that is below Remote Standby.
3. Enter the time requirement in this format: HHMMSS.
4. Touch the Accept button.
10.17.4 Set the Remote Standby Input Mode
The Remote Standby Input Mode setting is enabled by one of three settings: Trigger, On/Off,
or Direct.
NOTE: This setting does not show if the remote standby option is not installed on the system.
To change the Remote Standby Input mode, do the steps that follow:
1. On the System Setup screen, touch the Heats Setup tab and then touch the Control
Page 1 tab.
2. Touch the Remote Standby Input Mode field that is below Remote Standby.
3. Touch mode in the list to select it.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Husky Altanium Matrix5 and is the answer not in the manual?

Husky Altanium Matrix5 Specifications

General IconGeneral
BrandHusky
ModelAltanium Matrix5
CategoryController
LanguageEnglish

Related product manuals