Change the Manual Standby and Remote Standby Setpoint Limits 73
User Guide v 1.0 — February 2020 Making Adjustments
7. Touch the Power Minimum field and enter a percentage value.
8. Touch the Accept button.
9. Touch the Power Maximum field and enter a percentage value.
10. Touch the Accept button.
7.6.8.2 Change the Manual Standby and Remote Standby Setpoint Limits
There could be a condition when it is necessary to decrease the temperatures in the mold for
a period of time. This is done under the Manual Standby drop-down tab (or Remote Standby
drop-down tab from a remote location as an option), so it is not necessary to change the
operation temperature setpoint. Set the temperatures for the heaters in the mold to cool
down to when the system is in Standby (Manual and Remote). The default temperature for
both the manual and remote standby setpoints is 121 °C (250 °F).
7.6.8.2.1 Change the Manual Standby Setpoint Limits
To change a Manual Standby setpoint and limits for a zone, do the steps that follow:
1. Touch the zone to be changed on the Quick Set screen.
2. Touch Manual Standby drop-down tab.
3. Touch the Temperature Setpoint field and enter a temperature value.
4. Touch the Accept button.
5. Touch the Temperature Minimum field and enter a temperature value.
6. Touch the Accept button.
7. Touch the Temperature Maximum field and enter a temperature value.
8. Touch the Accept button.
9. Touch the Power Setpoint field and enter a percentage value.
10. Touch the Accept button.
11. Touch the Power Minimum field and enter a percentage value.
12. Touch the Accept button.
13. Touch the Power Maximum field and enter a setpoint percentage value.
14. Touch the Accept button.
7.6.8.2.2 Change the Remote Standby Setpoint Limits
To change a Remote Standby setpoint and limits for a zone, do the steps that follow:
1. Touch the zone to be changed on the Quick Set screen.
2. Touch the Remote Standby drop-down tab.
3. Touch the Temperature Setpoint field and enter a temperature value.
4. Touch the Accept button.
5. Touch the Temperature Minimum field and enter a temperature value.
6. Touch the Accept button.
7. Touch the Temperature Maximum field and enter a temperature value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Husky Altanium Matrix5 and is the answer not in the manual?

Husky Altanium Matrix5 Specifications

General IconGeneral
BrandHusky
ModelAltanium Matrix5
CategoryController
LanguageEnglish

Related product manuals