Standby Operation Description 131
User Guide v 1.0 — February 2020 System Setup
10.17.5 Standby Operation Description
The settings for manual and remote standby operations are described in Table 10-8 and
Table 10-9.
If it is necessary to cancel the manual standby duration timer, touch the Start or Stop
buttons.
Table 10-8 Manual Standby Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled
Operation - STANDBY Button Select
0:00:00 ---- ---- ---- ---- System enters Standby indefinitely.
X:XX:XX ---- ---- ---- ---- System remains in Standby until the
timer completes.
Table 10-9 Remote Standby Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled
Operation - STANDBY Button Select
---- 0:00:00 0:00:00 Trigger ---- System does not enter Standby,
because no timers are set.
---- 0:00:00 X:XX:XX Trigger ---- System immediately enters and
remains in Standby until the timer
completes.
---- X:XX:XX X:XX:XX Trigger No System delays for a specified time and
then enters Standby until the timer
completes.
---- X:XX:XX 0:00:00 Trigger No System delays for specified time and
then enters Standby indefinitely.
---- X:XX:XX X:XX:XX Trigger Yes System delays for a specified time and
then enters Standby until the timer
completes. If the input signal changes
state while the delay timer is active,
the delay timer is reset to the specified
value.
---- X:XX:XX 0:00:00 Trigger Yes System delays for specified time and
then enters Standby indefinitely. If the
input signal changes state while the
delay timer is active, the delay timer is
reset to the specified value.
---- 0:00:00 0:00:00 ON/OFF ---- System enters Standby until the input
signal is not active.
---- 0:00:00 X:XX:XX ON/OFF ---- System enters Standby until the input
signal is not active or the timer
completes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Husky Altanium Matrix5 and is the answer not in the manual?

Husky Altanium Matrix5 Specifications

General IconGeneral
BrandHusky
ModelAltanium Matrix5
CategoryController
LanguageEnglish

Related product manuals