GRT9165 OPERATOR MANUAL OPERATING CONTROLS AND FEATURES
3
CONTROLS AND FEATURES EXTERNAL TO
THE CAB
Outrigger Removal Control Box
An Outrigger Removal Control Box (Figure 3-33) is located
on the left front and right rear sides of the carrier.
The front and rear Outrigger Removal Control Boxes include
switches for engaging and disengaging the large pins that
secure the related outrigger box to the carrier.
Refer to Outrigger Removal and Installation, page 5-29 for
complete procedures on removing and installing the
outriggers boxes.
Pin Enable Switch
The Pin Enable Switch (1, Figure 3-33) is a momentary
three-position switch with center position maintained.
The Pin Enable Switch is used to enable and disable the Pin
Control Switch (2, Figure 3-33). Move switch to the upper or
lower ON position and hold to enable the Pin Control Switch
to operate. Release the switch and let it return to the center
OFF (disable) position.
Pin Control Switch
The Pin Control Switch (2, Figure 3-33) is a momentary
three-position switch with center position maintained.
The Pin Control Switch is used to engage and disengage the
large pins that secure the related outrigger box to the carrier.
With the Pin Enable Switch (1, Figure 3-33) positioned to
ON, move the Pin Control Switch to the left and hold to
disengage the outrigger box pins. With the Pin Enable
Switch positioned to ON, move the Pin Control Switch to the
right and hold to engage the outrigger box pins.
Bridging Switch (CE Certified Cranes)
The Rated Capacity Limiter (RCL) system, when
programmed accurately, will lock out the following crane
functions—boom up/down, telescope extend, and hoist up—
when a lift is attempted at or above crane capacity, or when a
two-block condition exists.
Locking out these functions prevents the overload or
two-block condition from worsening.
WARNING
Overload Hazard!
The Bridging Switch prevents the function lockouts from
activating.
When the Bridging Switch is activated, the operator must
make sure that the crane is not overloaded.
Do not operate crane with RCL overridden during normal
operations.
FIGURE 3-33
Item Description
1 Pin Enable Switch
2 Pin Control Switch
1
2

Table of Contents

Other manuals for Manitowoc Grove GRT9165

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT9165 and is the answer not in the manual?

Manitowoc Grove GRT9165 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT9165
CategoryConstruction Equipment
LanguageEnglish

Related product manuals