MAINTENANCE AND LUBRICATION GRT9165 OPERATOR MANUAL
6-34 Published 7-23-2020, Control # 668-02
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Approximate
Capacity
Service Interval
Service
Application
Lift Cylinder Lubrication
39
Lower Lift
Cylinder Pivot Pin
Figure 6-17 L
Until grease
extrudes
Every 100 hours, or
1 month, whichever
interval comes first
LUBRICATE
1 grease fitting,
1 service point
See NOTE 43.
See NOTE 44.
NOTE 43: DO NOT USE non semi-synthetic lubricant. Use of non-approved lubricant may damage components.
NOTE 44: Before operating crane in cold weather (arctic) ambient temperatures below -9°C (+15°F), Standard grease
must be fully purged and replaced with Cold Weather grease meeting Grove U.S. L.L.C. specifications as
shown in Table 6-4: Approved Lubricant Reference Table, page 6-11 in this Operator Manual. See also your
GRT9165 Service Manual for specified maintenance and lubrication instructions.
CAUTION
Possible Equipment Damage!
Use semi-synthetic or synthetic lubricants as listed in Section 6 of this Operator Manual. See
also your Service Manual for maintenance and lubrication instructions. Use of non-approved,
non semi-synthetic lubricant may damage components and/or invalidate published lubricant
intervals. Failure to follow this instruction may cause damage to equipment.