Grove Published 7-23-2020, Control # 668-02 3-13
GRT9165 OPERATOR MANUAL OPERATING CONTROLS AND FEATURES
3
Momentary Limit Bypass Switch (Non-CE
Certified Cranes)
The Rated Capacity Limiter (RCL) system, when
programmed accurately, will lock out the following crane
functions—boom up/down, telescope extend, and hoist up—
when a lift is attempted at or above crane capacity, or when a
two-block condition exists.
Locking out these functions prevents the overload or
two-block condition from worsening.
These same crane functions are locked out initially after the
crane engine is started and before the RCL system has been
programmed.
The Limit Bypass Switch (14, Figure 3-9) is a three-position,
momentary type rocker switch located on the right overhead
control panel.
During certain rigging work or to recover the crane, push and
hold the top or bottom of the rocker switch to bypass the
following limiter systems on the crane.
Push and hold bottom
of rocker switch to bypass the
following limiter systems and their crane function lockouts:
Anti-Two-Block System (boom up/down, telescope
extend, hoist up)
3rd Wrap Limiter System (hoist down)
The following indicators come on to indicate the limiters are
bypassed:
Anti-Two-Block Indicator is flashing (7, Figure 3-14)
3rd Wrap Indicator is flashing (in Alerts Area of ODM,
Figure 4-74)
Push and hold top
of rocker switch to bypass the following
limiter systems and their crane function lockouts:
RCL System (boom up/down, telescope extend, hoist
up)
Anti-Two-Block System (boom up/down, telescope
extend, hoist up)
3rd Wrap Limiter System (hoist down)
Working Range Limiter (WRL) System
Carrier Avoidance System
-29°C Temperature Limiter System (optional)
The following indicators come on to indicate the limiters are
bypassed:
Bypass 1 Pressed Indicator is on (2, Figure 4-208)
RCL Bypass Active Indicator is on (1, Figure 4-208)
RCL Shutdown Warning Indicator is flashing
(5, Figure 3-14)
Anti-Two-Block indicator is flashing (7, Figure 3-14)
3rd Wrap indicator is flashing (Figure 4-75)
Working Range Limiter (WRL) indicator is flashing
(Figure 4-75 and Figure 4-78)
Low Boom Angle Indicator is flashing (Figure 4-75)
-29°C Temperature Limiter Indicator is flashing
(Figure 4-75)
All crane function lockouts are bypassed while the Limit
Bypass Switch is held in the actuated position.
Limit Bypass Set-Up Switch (CE Certified
Cranes)
The Rated Capacity Limiter (RCL) system, when
programmed accurately, will lock out the following crane
functions—boom up/down, telescope extend, and hoist up—
when a lift is attempted at or above crane capacity, or when a
two-block condition exists.
Locking out these functions prevents the overload or
two-block condition from worsening.
These same craning functions are locked out initially after
the crane engine is started, and before the RCL system has
been programmed.
The Limit Bypass Set-up Switch (14, Figure 3-9) is a
three-position, momentary type rocker switch located on the
right overhead control panel.
WARNING
Overload Hazard!
The Limit Bypass Switch is used to override the RCL
system during some rigging activities.
When the Limit Bypass Switch is activated, the operator
must make sure that the crane is not overloaded.
Do not operate the crane with the RCL overridden during
normal operations.
WARNING
Overload Hazard!
The Limit Bypass Switch prevents the function lockouts
from activating.
When the Lift Bypass Switch is activated, the operator
must make sure that the crane is not overloaded.
Do not operate the crane with the RCL overridden during
normal operations.

Table of Contents

Other manuals for Manitowoc Grove GRT9165

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT9165 and is the answer not in the manual?

Manitowoc Grove GRT9165 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT9165
CategoryConstruction Equipment
LanguageEnglish

Related product manuals