EasyManuals Logo
Home>Manitowoc>Construction Equipment>Grove GRT9165

Manitowoc Grove GRT9165 User Manual

Manitowoc Grove GRT9165
476 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
Grove Published 7-23-2020, Control # 668-02 3-11
GRT9165 OPERATOR MANUAL OPERATING CONTROLS AND FEATURES
3
Heater/Air Conditioner Fan Speed Switch
The Heater/Air Conditioner Fan Speed Switch (1, Figure 3-9)
is located on the right overhead control panel.
The rotary switch controls the cab fan speed and volume of
heated or cooled air output. Settings are off, low speed,
medium speed, and high speed.
Turn the rotary switch clockwise to increase fan air speed.
Turn rotary switch counterclockwise to reduce fan air speed.
Turn rotary switch to the fully counterclockwise position to
stop fan.
Heater/Air Conditioner Temperature Control
Switch
The Heater/Air Conditioner Temperature Control Switch
(2, Figure 3-9) is located on the right overhead control panel.
The rotary switch controls the temperature of the air coming
out of the heater/air conditioner vents.
Turn the rotary switch clockwise to increase the air
temperature. Turn the rotary switch counterclockwise to
decrease the air temperature.
Fresh Air/Recirculation Air Switch
The Fresh Air/Recirculation Air Switch (3, Figure 3-9) is
located on the right overhead control panel.
The switch controls how outside air is drawn into the cab.
Use Recirculation mode for maximum air conditioner
performance in warm climates.
Push left side of the switch to draw outside air into the cab,
when operating the heater system or air conditioner system.
Push right side of the switch to recirculate the air inside the
cab, and bring a small amount of outside air into the cab.
Boom-Mounted Lights Motor Switch
(Optional)
The Boom-Mounted Lights Motor Switch (4, Figure 3-9) is
located on the right overhead control panel.
The switch controls the direction to which the boom-mounted
lights point. The switch is a three-position momentary rocker
switch with center maintained position being OFF.
Push and hold top of the switch to point the lights up. Push
and hold bottom of the switch to point the lights down.
Release the switch when the lights are pointing in the
desired direction.
Boom-Mounted Lights Switch (Optional)
The Boom-Mounted Lights Switch (5, Figure 3-9) is located
on the right overhead control panel.
The switch controls the work lights mounted to the boom
base section.
Push top of the switch to cause the lights to come on. Push
bottom of switch to cause the lights to go off.
Cab-Mounted Lights Switch
The Cab-Mounted Lights Switch (6, Figure 3-9) is located on
the right overhead control panel.
The switch controls the work lights mounted on the bottom
front of the superstructure cab.
Push top of switch to cause the lights to come on. Push
bottom of switch to cause the lights to go off.
Front Window Wiper and Washer Switch
The Front Window Wiper and Washer Switch (7, Figure 3-9)
is located on the right overhead control panel.
The switch is a six-position toggle switch with integral rocker
switch that controls the front window wiper and washer.
Push toggle switch up to operate the front window wiper at a
slow intermittent speed. Push toggle switch farther up to
operate the wiper at a faster speed. Pull toggle switch down
to stop operating the front window wiper.
Push and hold top of rocker switch to spray the windshield
with windshield washer fluid for cleaning. Release switch
after the desired amount of windshield washer fluid has been
sprayed onto the windshield.
Skylight Wiper and Washer Switch
The Skylight Wiper and Washer Switch (8, Figure 3-9) is
located on the right overhead control panel.
The switch is a six-position toggle switch with integral rocker
switch that controls the skylight wiper and washer on top of
the cab.
Push toggle switch up to operate the skylight window wiper
at a slow intermittent speed. Push toggle switch farther up to
operate the wiper at a faster speed. Pull toggle switch down
to stop operating the skylight window wiper.
Push and hold top of rocker switch to spray the skylight
window with window washer fluid for cleaning. Release
switch after the desired amount of window washer fluid has
been sprayed onto the skylight.
Increment/Decrement – Start/Stop Switch
The Increment/Decrement Start/Stop Switch
(9, Figure 3-9) is located on the right overhead control panel.
The switch is a three-position momentary rocker switch with
center maintained position being OFF. Use this switch to
adjust engine operating speed and to start and stop the
engine.

Table of Contents

Other manuals for Manitowoc Grove GRT9165

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT9165 and is the answer not in the manual?

Manitowoc Grove GRT9165 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT9165
CategoryConstruction Equipment
LanguageEnglish

Related product manuals