EasyManuals Logo
Home>Emerson>Measuring Instruments>LMS1000

Emerson LMS1000 User Manual

Emerson LMS1000
485 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
User Instructions Section 5847
Spec. Nos. 586505000 and 5865055000 (Model LMS1000) Issue AL, July 24, 2006
Chapter 3. Commands Page 3-27
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
ALARMS
Description: Lists active analog, binary, function, relay, and LED alarms and their
channel number. Also lists self diagnostic alarms.
Command Level: 1
Syntax: ALARMS [channel_type] [channel_designator] [channel_range]
[node_designator] [node_range] [group_designator] [search_text]
A [channel_type] [channel_designator] [channel_range] [node_designator]
[node_range] [group_designator] [search_text]
Comments: Analog and function channel alarm information includes the present value,
the unit of measure, and which alarm setpoint has been exceeded. Each type of alarm
can be viewed separately by entering the command ALARMS [node_designator]
[node_range] followed by a space and then the character A for analog, B for binary, R for
relay, L for LED, F for function, G for group, or U for user.
Notes: Analog and binary channels are automatically mapped to MCA parameters when
the VPS or LPS MCA Interface is used. Alarm information for these analog and binary
channels can be viewed using the ALARMS command and options. Refer to Tables 2-1
through 2-3 for a correlation between channels and mapped VPS MCA and LPS MCA
parameters. To view alarm information of just the VPS, use the ALARMS VORTEX
(ALARMS V) command and options.
Related Commands: ALARMS VORTEX
Example:
Command<1>: ALARMS
SYSTEM HARDWARE ALARMS:
I/O Network Failure
Unexpected Response received from node 02
Unable to communicate to node 03
Unrecognized node assembly found
Unexpected reset on node 05
Configuration mismatch on node 06
Assembly mismatch on node 07
Hardware mismatch on node 08
I/O card 01 on node 09 failed
Analog channel 1008 configuration failure
I/O card 02 on Main chassis failed
I/O card 03 on Main chassis does not match recorded the type
I/O card 07 on Main chassis is not a recognized type
ANALOG CHANNEL ACTIVE ALARMS AS OF 11:24:16 ON 01/01/01.
Chan Description Value Units Alarm Limit and Class
A0001.2L Analog Channel 1 +20.3 Amps 20.0 H - Hi Limit 2 MAJOR
BINARY CHANNEL ACTIVE ALARMS AS OF 11:24:18 ON 01/01/01.
Chan Description Status Alarm Status / Class
B0001 Binary Channel 1 CO active MINOR
RELAY CHANNEL ACTIVE ALARMS AS OF 11:24:20 ON 01/01/01.
Chan Description Status Alarm Status / Class

Table of Contents