RETRIEVE-PERFORMANCE MONITORING
(RTRV-PM-{EQPT|ALL})
Referenced In: TR-NWT-000833, Issue 5; pg. 4-307
General Description: Instructs LMS1000 to send its current set of Performance
Monitoring (PM) data associated with one or more equipment units, facilities, etc. within
LMS1000.
Parameters are provided to retrieve past PM data for LMS1000s that can store a history
of performance monitoring information.
The TL1 command language allows for reporting of Performance Monitoring information,
enabling/disabling of these reports, and scheduling of these reports. In addition, the TL1
commands for Performance Monitoring can specify the equipment unit(s) on which
performance monitoring is to be done. LMS1000 does not currently have these types of
capabilities for statistical information.
Related Commands: None
LMS1000 Access Level: 1
LMS1000 Equivalent: STATS
LMS1000 Input Format Variations:
<aid>
Use of the command code modifier ALL causes retrieval of Performance Monitoring (PM)
data for all access identifiers of the proper type. If the command code modifier is ALL,
the value of the access identifier parameter must be ALL. A NULL value is not permitted
for this parameter. Invalid values received for this parameter return an error response
with the error code IIAC.
<montype>
Specifies the type of monitored parameter for which a value is requested. This
parameter is not supported by LMS1000. The only valid value for this parameter is ALL.
An ALL value for this parameter requests all types of monitored parameters be retrieved.
Invalid values received for this parameter return an error response with the error code
IDNV.
<monlev>
Specifies the discriminating level for the requested monitored parameter. This parameter
is not supported by LMS1000. The only valid value for this parameter is NULL. A NULL
value causes the parameter to default to 1-UP. Invalid values for this parameter return
an error response with the error code IDNV.
<locn>
This parameter does not apply to LMS1000. The only valid value for this parameter is
NULL. Invalid values for this parameter return an error response with the error code
IDNV.