User Instructions Section 5847
Spec. Nos. 586505000 and 5865055000 (Model LMS1000) Issue AL, July 24, 2006
Chapter 3. Commands Page 3-29
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
ALARMS VORTEX
Description: Lists active VPS Alarms.
Command Level: 1
Syntax: ALARMS VORTEX, ALARMS VORTEX SYSTEM, ALARMS VORTEX
PCU[PCU_number], ALARMS VORTEX LVD, ALARMS VORTEX SHUNT,
ALARMS VORTEX MCA, ALARMS VORTEX SUBSYSTEM
A V, A V SYSTEM, A V PCU[PCU_number], A V LVD, A V SHUNT, A V MCA
Comments: Alarms of a specific VPS entity can be viewed separately by entering the
command ALARMS V followed by a space and then the entity specifier (SYSTEM,
PCU[PCU_number], LVD, SHUNT, MCA, or SUBSYSTEM).
Notes:
PCU failure status is only displayed for PCUs installed in the system.
The following is displayed if there are no active MCA alarms.
VORTEX MCA STATUS AS OF xx:xx:xx ON xx/xx/xx.
Description Alarm Status
No active MCA alarms
The following is displayed if there are no active SHUNT alarms.
SHUNT ACTIVE ALARMS AS OF xx:xx:xx ON xx/xx/xx
Description Alarm Status
No active SHUNT alarms
The following is displayed if there are no digital LVDs installed in the system.
LVD ACTIVE ALARMS AS OF xx:xx:xx ON xx/xx/xx.
Description Alarm Status
No digitally controlled LVDs installed
Potentiometer controlled LVDs are displayed only when the LVD circuit is active.
The following is displayed if there are no active LVD alarms.
LVD ACTIVE ALARMS AS OF xx:xx:xx ON xx/xx/xx.
Description Alarm Status
No active LVD alarms
The following is displayed if there are no active alarms on a selected PCU.
PCU## ACTIVE ALARMS AS OF xx:xx:xx ON xx/xx/xx.
Alarm Status
No active PCU alarms
The following is displayed if the selected PCU is not installed in the system.
Command<2>: ALARMS V PCU[n]
Which PCU (1-56)?
PCU ## not installed in system
The following is displayed if an invalid PCU number is entered.
Command<2>: ALARMS V PCU[n]