User Instructions Section 5847
Spec. Nos. 586505000 and 5865055000 (Model LMS1000) Issue AL, July 24, 2006
Chapter 3. Commands Page 3-319
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
DELETE-USER-SECURITY
(DLT-USER-SECU)
Referenced In: TR-NWT-000835, Issue 3; pg. 3-45
General Description: Deactivates an LMS1000 user.
When executed, the command sets the USER ACTIVE attribute of this user’s LMS1000
user configuration to N. This command conforms to the LMS1000’s restriction that a user
may not deactivate oneself. If a user attempts to deactivate oneself, then an error
response is returned with the error code PIUC.
An entry is made in the LMS1000’s event log indicating this command was executed by
the current sessions user. The event description indicates that the specified user was
deactivated.
Related Commands: None
LMS1000 Access Level: 6
An error response with the error code PICC is returned if this command is entered by a
valid user whose level of access is less than the access level of this command.
LMS1000 Equivalent: None
LMS1000 Input Format Variations:
<aid>
The access identifier (<aid>) parameter is the same value as the user identifier (<uid>)
parameter for the user who is being deactivated. The user identifier parameter is the
NAME attribute from this user’s LMS1000 user configuration. Invalid values received for
this parameter return an error response with the error code IIAC.
A user cannot deactivate oneself. If a user attempts to delete oneself, than an error
response is returned with the error code PIUC.
LMS1000 Response Format Variations: None