User Instructions Section 5847
Spec. Nos. 586505000 and 5865055000 (Model LMS1000) Issue AL, July 24, 2006
Chapter 3. Commands Page 3-161
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
SET COM
Description: Permits configuration of the local port data rate.
Note: Modem port communications parameters cannot be set. The data rate for the
local port is the only communications parameter that can be changed.
Command Level: 6
Syntax: SET COM
SE CO
Comments: The data rate, parity, number of data bits, and number of stop bits appear in
the order listed, separated by commas. Any local port changes will take effect
immediately after the Y key is pressed to initiate the change. Refer to Table 3-1 for a
listing of available local port communications formats.
Data Rate
(Bits/s)
Parity
Data
Bits
Stop
Bits
300, 600, 1200, 2400,
4800, 9600, or 19200
n
for none 8 1
Default setting shown in underlined type.
Table 3-1
Available Local Port Communications Parameters
Notes: none
Related Commands: COM
Example:
Command<6>: SET COM
Local Comm Port Setup:2400,n,8,1
Enter new setup:19200
Re-initialize Port (Y or N):Y
Local Comm Port Setup:19200,n,8,1