1. PITP can be enabled or disabled at four levels: global, port, VLAN, and service
port levels. This function takes effect only after it is enabled at the four levels.
Among the four levels, PITP is disabled only at the global level by default.
– The global level: In global config mode, run the pitp enable pmode, pitp
forward pmode, or pitp rebuild pmode command to enable PITP at the
global level.
In the preceding commands, the enable, forward, and rebuild parameters
can all enable PITP but provide different packet processing policies on the
OLT. Select one of them based on site requirements. For details, see the
pitp command.
– The port level: In global config mode, run the pitp port or pitp board
command to enable PITP at the port level.
– The VLAN level:
a. In global config mode, run the vlan service-profile command to create
a VLAN service profile.
b. Run the pitp enable command to enable PITP at the VLAN level.
c. Run the commit command to make the profile configuration take effect.
d. Run the quit command to quit the VLAN service profile mode.
e. Run the vlan bind service-profile command to bind the created VLAN
service profile to a VLAN.
– The service port level: In global config mode, run the pitp service-port
command to enable PITP at the service port level.
2. On the OLT, run the pitp permit-forwarding service-port command with the
enable parameter selected, to allow ONU PPPoE packets to carry a vendor tag.
----End
12.4.2.12 Verifying Services
In the FTTO scenario, ONUs are installed at users' houses or in business buildings which are
far away from the central equipment room. ONUs provide remote service verification methods
including PPPoE dialup emulation, call emulation, and multicast emulation to facilitate
configuration and commissioning engineers to verify services remotely after service
configuration.
Prerequisites
ONUs and upper-layer devices have been connected properly. The BRAS and MGC/IMS have
been configured.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
12 FTTO Configuration(SOHO and SME)
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1229

Table of Contents

Other manuals for Huawei SmartAX MA5600T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5600T and is the answer not in the manual?

Huawei SmartAX MA5600T Specifications

General IconGeneral
BrandHuawei
ModelSmartAX MA5600T
CategoryControl Unit
LanguageEnglish

Related product manuals