EasyManuals Logo
Home>Huawei>Control Unit>SmartAX MA5600T

Huawei SmartAX MA5600T User Manual

Huawei SmartAX MA5600T
1979 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #216 background imageLoading...
Page #216 background image
Example
To query the log records of all users within the period from 10:00:00 on 2009-08-24 to 18:00:00
on 2009-08-24, do as follows:
huawei>display log
{ all<K>|cli<K>|failure<K>|index<K>|memory<K>|name<K>|snmp<K> }:all
{ <cr>|start-date<D><yyyy-mm-dd> }:2009-08-24
{ -<K>|<cr>|start-time<T><hh:mm:ss> }:10:00:00
{ -<K>|<cr> }:-
{ end-date<D><yyyy-mm-dd> }:2009-08-24
{ <cr>|end-time<T><hh:mm:ss> }:18:00:00
Command:
display log all 2009-08-24 10:00:00 - 2009-08-24 18:00:00
---------------------------------------------------------------------------
No. UserName Domain IP-Address
65 test03 -- 10.71.42.55
Time: 2009-08-24 17:14:48
Cmd: switch language-mode
---------------------------------------------------------------------------
No. UserName Domain IP-Address
64 private -- 10.78.217.35
Time: 2009-08-24 17:08:08
Cmd:
Index1: hwFrameIndex: 0
Index2: hwSlotIndex: 9
hwBackupServerIpAddr: 10.78.217.35
hwBackupMode: 3
hwBackupFileName: /bmsuser/7341374.poz
hwBackupContent: 68
hwBackupUserNam ...
---------------------------------------------------------------------------
No. UserName Domain IP-Address
63 private -- 10.78.217.35
---- More ( Press 'Q' to break ) ----
1.5.4 Checking the System Switchover
After the active/standby switchover is performed, the services of the active control board are
switched to the standby control board. This ensures that the services run in the normal state.
Prerequisites
l An active control board and a standby control board must be configured on the device, and
the cables must be connected correctly on the boards.
l The patch status of the active and standby control boards must be consistent with the
hardware environment.
Precautions
l If the data of the active and standby control boards is not completely synchronized, the
system prohibits the active/standby switchover.
NOTE
Run the display data sync state command to query the data synchronization status of the active and
standby control boards.
l When the communication between the active and standby control boards fails or the standby
control board is faulty, the system prohibits the active/standby switchover.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
1 Commissioning
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
191

Table of Contents

Other manuals for Huawei SmartAX MA5600T