The configured static routes can be queried in an IPv6 routing table by running the display ipv6
routing-table command.
16.3.1.7 Configuring a Management Channel Between an OLT and a D-CMTS
This section describes how to configure a management channel between an optical line terminal
(OLT) and a distributed cable modem termination system (D-CMTS). After the configuration,
you can log in to the D-CMTS from the OLT and configure the D-CMTS.
Prerequisites
The MA5633 management policy is set to stand-alone. To do so, run the sysman centralized-
mgmt primary command.
Data Plan
Item Data Remarks
OLT GE port: 0/3/0
l Do not enable both the remote
software commissioning using
PON upstream transmission and the
remote software commissioning
using GE upstream transmission.
l Ensure that the database of a newly
deployed D-CMTS is empty.
Otherwise, the remote software
commissioning using GE upstream
transmission cannot be used.
l Only the network management
parameters defined in SNMPv1 and
SNMPv2 are supported.
l When the D-CMTS automatically
obtains management parameters, it
automatically generates a default
route that can be restored. However,
the default route may not be proper
in service configuration. Therefore,
you are advised to add a new route
and delete the default one after the
D-CMTS management channel is
available.
l After the D-CMTS automatically
obtains management parameters,
the remote software commissioning
function is automatically disabled if
configurations are issued to the D-
CMTS through the U2000. To
modify the D-CMTS management
parameters, remotely log in to the
Management VLAN
and IP address of the
D-CMTS
ID of the management
VLAN: 8
Type of the management
VLAN: smart
Management IP address:
192.168.50.2/24
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
16 OptiCable D-CMTS Configuration (MA5633 Working as
a Standalone NE)
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1692

Table of Contents

Other manuals for Huawei SmartAX MA5600T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5600T and is the answer not in the manual?

Huawei SmartAX MA5600T Specifications

General IconGeneral
BrandHuawei
ModelSmartAX MA5600T
CategoryControl Unit
LanguageEnglish

Related product manuals