April 2017
2-116
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
016-322, 016-323
Launch Issue
Status Indicator RAPs
016-322 JBA Account Full RAP
016-322 The cumulated accounting data reached the specified value (15,000).
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Advise the customer to perform a manual retrieval of machine data from their accounting
server.
3. Initialise the hard disk. Refer to dC355 Hard Disk Diagnostics. Advise the customer to
push the user accounts to the machine from their accounting server.
4. Ensure that all connectors on the ESS PWB, PL 3.10 Item 6 are securely connected.
Ensure all surface mounted modules are securely connected.
5. Reload the software, GP 4.
6. Perform the OF2 Special Boot Modes RAP.
016-323 B-Formatter Fatal Error RAP
016-323 Fatal error has occurred in the B-formatter task.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Ensure that all connectors on the ESS PWB, PL 3.10 Item 6 are securely connected.
Ensure all surface mounted modules are securely connected.
3. Reload the software, GP 4.
4. Perform the OF2 Special Boot Modes RAP.