User's Manual 66. Configuration Parameters Reference
Parameter Description
Web: Web and Telnet
Access List Table
EMS: Web Access
Addresses
[WebAccessList_x]
This table configures up to ten IP addresses that are permitted to
access the device's Web interface and Telnet interfaces. Access from
an undefined IP address is denied. When no IP addresses are defined
in this table, this security feature is inactive (i.e., the device can be
accessed from any IP address).
The default is 0.0.0.0 (i.e., the device can be accessed from any IP
address).
For example:
WebAccessList_0 = 10.13.2.66
WebAccessList_1 = 10.13.77.7
For a description of this parameter, see 'Configuring Web and Telnet
Access List' on page 73.
66.2.2 Web Parameters
The Web parameters are described in the table below.
Web Parameters
Parameter Description
Web: Password Change
Interval
[WebUserPassChangeIn
terval]
Defines the duration (in minutes) of the validity of Web login
passwords. When this duration expires, the password of the Web user
must be changed.
The valid value is 0 to 100000, where 0 means that the password is
always valid. The default is 1140.
Note: This parameter is applicable only when using the Web Users
table, where the default value of the 'Password Age' parameter in the
Web Users table inherits this parameter's value.
Web: User inactivity timer
[UserInactivityTimer]
Defines the duration (in days) for which a user has not logged in to the
Web interface, after which the status of the user becomes inactive and
can no longer access the Web interface. These users can only log in to
the Web interface if their status is changed (to New or Valid) by a
System Administrator or Master user.
The valid value is 0 to 10000, where 0 means inactive. The default is
90.
Note: This parameter is applicable only when using the Web Users
table.
Web: Session Timeout
[WebSessionTimeout]
Defines the duration (in minutes) of Web inactivity of a logged-in user,
after which the user is automatically logged off the Web interface.
The valid value is 0-100000, where 0 means no timeout. The default is
15.
Note: This parameter can apply to all users, or per user when set in
the Web Users table.
Web: Deny Access On
Fail Count
[DenyAccessOnFailCou
nt]
Defines the maximum number of failed login attempts, after which the
requesting IP address is blocked.
The valid value range is 0 to 10. The values 0 and 1 mean immediate
block. The default is 3.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Media 800 MSBR and is the answer not in the manual?

AudioCodes Media 800 MSBR Specifications

General IconGeneral
BrandAudioCodes
ModelMedia 800 MSBR
CategoryNetwork Router
LanguageEnglish

Related product manuals